Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


In dissolution test s1 stage we are getting one bowl 40 % out of 6 bowls what is the root cause you find and how proceed next step? ( Q is 80%)

Answers were Sorted based on User's Feedback



In dissolution test s1 stage we are getting one bowl 40 % out of 6 bowls what is the root cause you ..

Answer / nagabhushan

First raise the OOS and then investigate how it will come because it cross the S3 stage also

Is This Answer Correct ?    3 Yes 0 No

In dissolution test s1 stage we are getting one bowl 40 % out of 6 bowls what is the root cause you ..

Answer / haripriya

Conform Calibration for Temp , rpm and shaft positons etc for that bowl

Is This Answer Correct ?    0 Yes 0 No

In dissolution test s1 stage we are getting one bowl 40 % out of 6 bowls what is the root cause you ..

Answer / prashant mane

Also product was not stable or homogeneous.

Is This Answer Correct ?    0 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

why we use a particular hplc column for a particular compound give reasons?please

0 Answers   Dr Reddys, Indoco Remedies, Natco,


What is Delay & Dead Volume

2 Answers  


why we use kbr as constant in the FTIR ?

4 Answers  


How can you prepare 0.1% Phosphate buffer solution?

6 Answers  


What is AV value in test uniformity content ,describe calculation

1 Answers   Lupin,


what is rt and rrt? how we find rrt? relation between rt and rrt/

1 Answers   Cadila,


how the compound separate in coulunm,explain

0 Answers   Wockhardt,


why linerity not use in GC but use in HPLC ?

6 Answers  


According to ICH,India is coming under which climatic zones?

1 Answers   Cipla,


why SGF media used for dissolution . What is the use of it .can we use other media of lower pH instead ot this?

1 Answers  


What is Specificity ?

8 Answers   Dr Reddys,


What is the difference between high pressure gradient and low pressure gradient in hplc?

1 Answers   Cipla,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)