Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


what is rt and rrt? how we find rrt? relation between rt and rrt/



what is rt and rrt? how we find rrt? relation between rt and rrt/..

Answer / harshad raj

In HPLC & GC :
The RT means, in which time the main principle peak of component is retain in minute called RT as retention time. and the RRT means: in which time the impurity peaks are retained before and after the main principle peak and that retention time of impurity peaks called RRT, ie. relative retention time RRT to the base of main peak RT.
The relation between RT & RRT is always the main peak RRT is 1.0 and the impurity peak RRT calculation is IMPURITY PEAK RT / MAIN PEAK RT.
For example: The main peak RT is 15 MIn, and the Impurity RT is 5 Min,
The RRT of Main Peak is 15/15 = 1
The RRT of Impurity peak is 5/15 = 0.333...

Is This Answer Correct ?    33 Yes 3 No

Post New Answer

More Analytical Chemistry Interview Questions

What is the name of the detector used in TOC?

1 Answers   Lupin,


why are not used methonol in kf titrator to find out water content in ketones?

5 Answers   Piramal Healthcare,


what is the difference between Tailing Factor & Asymmetry

8 Answers   Ashish Life Science, BEC Chemicals, Jubilant,


IF HPLC CALIBRATION FAILED THEN WHAT YOU DO

6 Answers  


How is the Flame test performed?

4 Answers   Lupin,


what is the value of pH

11 Answers   Reddy Labs,


if tech transfer fails whay require to do?

0 Answers  


How much carbon loading in nomalphase columns?

5 Answers  


is it necessary to do HPLC calibration at wavelength 315nm if we are doing analysis at this wavelangth

0 Answers   Aarti Drugs,


Why only 1.2 million lux hours require in photostability study?

0 Answers  




0 Answers  


what is the maximum flow rate in prep hplc

1 Answers   Meril Life Science,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)