Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


How to connect another 24 volt dc power supply in circuit when previous power supply has become weak.what is the connection?

Answers were Sorted based on User's Feedback



How to connect another 24 volt dc power supply in circuit when previous power supply has become wea..

Answer / hiren

Parallel connection to Voltage source

Is This Answer Correct ?    5 Yes 0 No

How to connect another 24 volt dc power supply in circuit when previous power supply has become wea..

Answer / carl_ellis

A second power supply is wired in parallel with the first, but redundant/parallel power supplies should be decoupled from each other with power diodes, where each diode is forward biased on the power supply (+) output with the diode (-) coupled in common to the load).

The diodes need to be rated to carry the full current load. If diodes are not used, a severe fault in one of the power supplies could cripple the output of the 2nd power supply.

The isolation diodes must be installed on a heatsink to maintain operating temperature at a safe level. The power dissipation on the diode is determined by the product of the current passing through the diode and its "on" diode voltage drop.

Some recommend the use of Schottky diodes rather than silicon diodes becaus Schottky diode has a lower voltage drop so it runs cooler.

There are commercial diode decoupling/isolation packages sold with appropriately sized heat sinks to keep the diodes within temperature spec.

Carl Ellis
Measure First

Is This Answer Correct ?    3 Yes 1 No

Post New Answer

More Instrumentation Interview Questions

DEAR SIR/MADAM MY NAME IS ARKAPROVA BHATTACHARYYA.I AM A FRESHER INSTRUMENTATION ENGINEER.CAN YOU PLEASE SEND SOME QUESTION PAPERS OF GRADUATE ENGINEER TRAINEE EXAM OF DVC(DAMODAR VALLY CORPORATION).MY EMAIL IDs ARE arka_aec@rediffmail.com.

0 Answers  


what is vibration a part of proceess variable? if vibration is a part variables then how we minimize the actual vibration on machine on load,? vision of instrumentation contrl plz ans me IPGDL interview question

0 Answers  


What is principle of ultrasonic level transmitter?

3 Answers  


Hi Frnds , If Suppose 1 Pair cable of 1.5 sq mm is used for Transmitter and instead of 1.5 sq mm if i used 0.5 sq mm cable will the resistance change will occur and does it affect our transmitter reading. plz mail ur answer to ntnkamble@gmail.com plz immediately mail ur reply

1 Answers  


what happen if i install my pressure transmitter below the elevation of pipe in natural gas service. Also support your answer

3 Answers   C2C,


what is span value and zero ? and how set ?

0 Answers  


what is the advantage of submersible level transmitter compare to ultrasonic level transmitter?

0 Answers  


Hi at present i m wrking with tire industry as a manager having gud ctc. Nw I am selected for 1 of the best chemical industry but my ctc is lower than current n also i hv 2 compromize vit post as post is also lower. I hv 6 yrs of exp in various type of industry. Should i join chemical industry as there ar lot of gud instrument than tire? Financialy i can manage 4 more 2 yrs. Bt during wrking vit tire industry i found there is very less instrument n feel that opportunity is less. Pl ans quickly. I have less time to decide.

1 Answers  


what is the principle of vibration

3 Answers  


Square root calculation for dp flow transmitter?

0 Answers  


How to Calibrate Flammable gas detector in field

0 Answers  


LADDER LOGIC Can any body state Logic on following condition Instructions to use 1-XIC 2-XIO 3-Output ONLY Program Push 1st button On - 1st lamp should On Then Push 1st button Off - 1st Lamp Should remain on Push 2nd button On - 1st lamp should Off and 2nd lamp should On Then Push 2nd button Off - 2nd Lamp Should remain on.

4 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)