The ff slab casted its thickness
100mm.2nd floor slab will be casting its
300 mm.how we shall be given suppot to
that 300mm thk slab.ple way me

Answers were Sorted based on User's Feedback



The ff slab casted its thickness 100mm.2nd floor slab will be casting its 300 mm.how we shall be..

Answer / unnu

Once the first floor slab is set , you can give support for the 2nd floor slab. Nothing is going to give away.FF slab will be already supported by columns

Is This Answer Correct ?    6 Yes 1 No

The ff slab casted its thickness 100mm.2nd floor slab will be casting its 300 mm.how we shall be..

Answer / ajay saini

actually this condition is due to failure of planning or due to change in planning.but if you have planning of this type of work you should design the load bearing members according to your building design.

Is This Answer Correct ?    1 Yes 1 No

The ff slab casted its thickness 100mm.2nd floor slab will be casting its 300 mm.how we shall be..

Answer / divusp

In this case, we can strengthen ff slab by giving props from gf so that ff slab can sustain over load coming from sf slab 

Is This Answer Correct ?    1 Yes 1 No

Post New Answer

More Civil Engineering Interview Questions

What is meant by dimensioning?

0 Answers  


in 1:4,1:6 and 1:8 cement mortar mix how much water required? and find water cement ratio?

1 Answers  


How much percentage of overlap allowed in distribution steel as per IS Code.

2 Answers   Don Consult, India Cements,


What is the use of extend command?

0 Answers  


what is bolt value?

2 Answers   L&T, REC,






What is tha cross secional area of cover block

3 Answers   Raheja,


How do you determine or evaluate success?

7 Answers   Essar, Shell,


Column is a compression member then why we provide reinforcement on column?

1 Answers   Simplex, Thermax, Vihaan Group,


"Why you consider yourself suitable for the post"

17 Answers   Banking, CSE, IIP, IREDA, L&T, Maytas, McHugh, Nations Trust Bank, Teaching, Techkriti IIT Kanpur, Xantium Integrated Solutions,


What are the causes of building collapse?

0 Answers  


what should be the minimum cross sectional dimensions of column for any given loads????

1 Answers  


Doul Bar reinforcement and details of drawing.

0 Answers   Atlanta Infrastructure,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4452)
  • Electrical Engineering Interview Questions Electrical Engineering (16637)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)