How will you calibrate an interface level trol/normal level
trol in line and in w/s?



How will you calibrate an interface level trol/normal level trol in line and in w/s?..

Answer / faiyaz ahmad

Level troll is process or technique which is used to measure level in close tank or vessel
calibration of level troll weight the displacer and measure the diameter of displacer through vernier caliper after that calculate in computer then i will hookup link in apparatus and then
25% 50% 75% 100% again reverse 75% 50% 25% o% 4 mA 8mA 12mA 16mA 20mA

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

What is mean by analytical instrumentation?

0 Answers  


why using negative supply for bentley nevada vibration system ?

0 Answers  


What is difference between profibus and modbus communication

2 Answers   GMR,


What is force balance principle? State some of its’ advantages.

0 Answers  


Why we use 4 to 20 mA, (This is International Standard) instaed of this can we use 4-16, or 4-24 or 3- 15 or any other range

13 Answers   ONGC,






I faced several time siemens ps2 positioner automatically getting Chang in it's set point direction after auto calibration  So is there any causes biside this or  any  permissives ?

0 Answers  


Can we use PLC in Hazardous Area?

2 Answers   MNHG,


why generation of syncronized generator increases when frequency of grid is less then 50Hz & generation decreases when grid frequency goes up from 50 Hz, as comparision with set value entered in govering panel?

1 Answers  


what is the advantage of submersible level transmitter compare to ultrasonic level transmitter?

0 Answers  


what is the procedure to isolate flow a transmitter and flushing it?

8 Answers   Petrofac,


We have ZR22G-100-S-A-E-T-T--E-A/CV/F1 Model Zirconia Oxygen analyser which is Yokogawa make. I kept the analyser in Flue gas path at Air pre heater area. My plant is 7.5MW Biomass power plant. For a particular fuel, Coconut Husk which contains Sodium and Potassium chlorides iam not getting proper reading, Analyser output always Zero. I calibrated the analyser and it is OK. For Other fuels like Wood chips, Cholam waste, DOB, Groundnutshells, Ply wood waste and all iam getting actual percentage of Oxygen. What is the main reason behind this draw back?

2 Answers  


Describe a time when you anticipated potential problems and developed preventive measures.

0 Answers   Hotel Management,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4452)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)