How will you calibrate an interface level trol/normal level
trol in line and in w/s?

Answer Posted / faiyaz ahmad

Level troll is process or technique which is used to measure level in close tank or vessel
calibration of level troll weight the displacer and measure the diameter of displacer through vernier caliper after that calculate in computer then i will hookup link in apparatus and then
25% 50% 75% 100% again reverse 75% 50% 25% o% 4 mA 8mA 12mA 16mA 20mA

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.

1839


why we should maintain neutral earth voltage below 1V while calibration? why cant it be 1.2V or 2V

2117


What is the use of gauge?

781


hii my name is sujith...i am preparing for HPVL GET 2010... so ,,,pls help me by send any previous questions or material to my site.....(Msujith_12@in.com) thank q

1546


Isometric drawings are generated during _________________ phase of a project

1715






few questions on RS 232,1 question on relationship of impedance and turns ratio, many questions on flowmeters

1692


what step is taken for ESD ( emergency shut down) in DCS REPLY to hashimka20009@gmail.com

1989


we want to control pump in let pressure and tank (for exp) our inlet line if water cam and pump will on and when our tank will full pump will off also if our inlet pressure low pump will off even tank not full.this pump i want to uses on our water supply line.

1369


how u calibrate pneumatic n motorized c/v?

1628


How to convert milliampares into flow??

1364


how to convert MA in to measuring values..and how mwasuring values into MA ?..plz ansr.i have intervw

2238


What pressure results for a flow transmitter of range 0- 180t/h in the dcs and 0-301mbar in the field using square root extraction. Kindly also suggest formulae for the percentages 0,25,50,75,100?

1627


how u choose thermowell lenght n pnumatic C/v size?

1758


applications of plc in printing and packaging?

1762


i want formula for flow control.am doing project in flow control using orifice . i know value of the flow level(Q) . upstream(p1) pressure, orifice diameter(Do) , pipe diameter(Di) and oil viscosity(Vi) how can i calculate downstream pressure

1551