In 120 m high RCC Chimney shell construction how we can
calculate the inner and outer dia of shell at every +1 m
level as this shell is inclined from bottom to top.
Answers were Sorted based on User's Feedback
Answer / sachin
BY CALCULATING THE SLOPE OF SHELL PER METER AND REDUCING
FROM OUTER AND INER DIA AT EVERY LEVEL WE CAN CALCULATE THE
ACTUAL DIA AT THAT STAGE.
| Is This Answer Correct ? | 14 Yes | 2 No |
Answer / n.c.kapri
in slipform technology ,we do a marking in spur beam from
center.drop the shawal from there and measure the distance
from inner wall to that marking,it will our I.D
ex:marking at 2.9m
distance from inner wall to that marking .475m
so inner dia =2.9+.475
=3.375m
now add the wall thikness in I.D & get outside dia
| Is This Answer Correct ? | 7 Yes | 1 No |
Answer / m.senthilkumar
(bottom outer dia- top outer dia)/ height=average reduce the
dia per 1mt
inner dia =outer dia is checked ok so just measurement wall
thickness is correct or not
example:
bottom outer dia=100mt top outer dia =82mt height=120mt wall
thickness=0.5mt
(100-82)/120=0.15mt each 1mt reduce the dia 0.15mt ok
+4m outer dia=(100-(4*.15))=99.40mt dia
+4m inner dia=(99.40-2*0.5(wall thickness)=98.40mt dia
chimney 90degree maintain =center point maintain 0 to 120mt&
check radius every +1mt
| Is This Answer Correct ? | 2 Yes | 0 No |
Answer / omkar
example:
bottom outer dia=100mt top outer dia =82mt height=120mt wall
thickness=0.5mt
(100-82)/120=0.15mt each 1mt reduce the dia 0.15mt ok
+4m outer dia=(100-(4*.15))=99.40mt dia
+4m inner dia=(99.40-2*0.5(wall thickness)=98.40mt dia
chimney 90degree maintain =center point maintain 0 to 120mt&
check radius every +1mtĀ
| Is This Answer Correct ? | 1 Yes | 1 No |
what is the difference between factor of safety and partial safety factor.??
what is the least count of staff ?
technical name of shuttering plywood
how many days we should curing for plastering,brickwork,concrete?
10 Answers Al Faraa, Alfaraa, CCCL, Consolidated Construction Consortium Limited, Wipro,
what is 3.14 indicates for cutting length of stirrups
What is Well Point System in Dewatering
What is the use of extruded feature in solidsworks?
A bill was raised by contractor which read as follows 1.) Excavation in normal soil upto 1.5m - 250 cum 2.) Excavation in normal soil 1.5m to 3m - 240 cum 3.) Excavation in soft rock - 350 cum 4.) Excavation in hard rock - 250 cum 5.) Filling with available soil - 825 cum 6.) Filling with bought out soil - 1100 cum How can I verify the above quantities, especially for item no. 5 & 6? What checks are necessary before releasing the bill ?
what is the percentage of tolerance in the steel bars
PLS.......... ANY ONE CAN FORWARD ME PREVIOUS QUESTION PAPER hpcl civil engg
what affect on the structure and related beam of slab when provide one way slab insteade of two way slab
what is M20 ?
3 Answers L&T, Sukhwani Constructions,
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)