In 120 m high RCC Chimney shell construction how we can
calculate the inner and outer dia of shell at every +1 m
level as this shell is inclined from bottom to top.
Answers were Sorted based on User's Feedback
Answer / sachin
BY CALCULATING THE SLOPE OF SHELL PER METER AND REDUCING
FROM OUTER AND INER DIA AT EVERY LEVEL WE CAN CALCULATE THE
ACTUAL DIA AT THAT STAGE.
| Is This Answer Correct ? | 14 Yes | 2 No |
Answer / n.c.kapri
in slipform technology ,we do a marking in spur beam from
center.drop the shawal from there and measure the distance
from inner wall to that marking,it will our I.D
ex:marking at 2.9m
distance from inner wall to that marking .475m
so inner dia =2.9+.475
=3.375m
now add the wall thikness in I.D & get outside dia
| Is This Answer Correct ? | 7 Yes | 1 No |
Answer / m.senthilkumar
(bottom outer dia- top outer dia)/ height=average reduce the
dia per 1mt
inner dia =outer dia is checked ok so just measurement wall
thickness is correct or not
example:
bottom outer dia=100mt top outer dia =82mt height=120mt wall
thickness=0.5mt
(100-82)/120=0.15mt each 1mt reduce the dia 0.15mt ok
+4m outer dia=(100-(4*.15))=99.40mt dia
+4m inner dia=(99.40-2*0.5(wall thickness)=98.40mt dia
chimney 90degree maintain =center point maintain 0 to 120mt&
check radius every +1mt
| Is This Answer Correct ? | 2 Yes | 0 No |
Answer / omkar
example:
bottom outer dia=100mt top outer dia =82mt height=120mt wall
thickness=0.5mt
(100-82)/120=0.15mt each 1mt reduce the dia 0.15mt ok
+4m outer dia=(100-(4*.15))=99.40mt dia
+4m inner dia=(99.40-2*0.5(wall thickness)=98.40mt dia
chimney 90degree maintain =center point maintain 0 to 120mt&
check radius every +1mtĀ
| Is This Answer Correct ? | 1 Yes | 1 No |
the beam size (450x1000) effective length is 19.0mts no intermediate supports and top 8nos 32dia and bot 32dia and condition is stragge lap. it is exceeding lap zones and exceed length of bars?
steam curing is not used in which cement
which type of cement uses for R.C.C. & why?
2 Answers Ideal Construction,
Please let me know the simplest way of Calculating mix designs for any grade.
what is scaffolding and state is purpose
What is meant by struct column And stub column
3 Answers L&T, Shoba Devlopers, TATA,
) Design a gussetted base for a column section consisting of one sc 250 with two cover plates 300 x 25 mm carrying an axial load of 2500 KN. The S.B.C. of soil is 250 KN/m2 and the permissible bearing pressure on concrete is 4000 KN.
how you confirm the hard stratum for driven cat in situ pile work?
Cement require for 1sqm
How to calculate cement required for m20,m5 grade
what is the mix design for M45 concrete
which is the cheapest type of flooring (say for using for 6 months in a factory building & dismantling it)?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)