In 120 m high RCC Chimney shell construction how we can
calculate the inner and outer dia of shell at every +1 m
level as this shell is inclined from bottom to top.
Answers were Sorted based on User's Feedback
Answer / sachin
BY CALCULATING THE SLOPE OF SHELL PER METER AND REDUCING
FROM OUTER AND INER DIA AT EVERY LEVEL WE CAN CALCULATE THE
ACTUAL DIA AT THAT STAGE.
| Is This Answer Correct ? | 14 Yes | 2 No |
Answer / n.c.kapri
in slipform technology ,we do a marking in spur beam from
center.drop the shawal from there and measure the distance
from inner wall to that marking,it will our I.D
ex:marking at 2.9m
distance from inner wall to that marking .475m
so inner dia =2.9+.475
=3.375m
now add the wall thikness in I.D & get outside dia
| Is This Answer Correct ? | 7 Yes | 1 No |
Answer / m.senthilkumar
(bottom outer dia- top outer dia)/ height=average reduce the
dia per 1mt
inner dia =outer dia is checked ok so just measurement wall
thickness is correct or not
example:
bottom outer dia=100mt top outer dia =82mt height=120mt wall
thickness=0.5mt
(100-82)/120=0.15mt each 1mt reduce the dia 0.15mt ok
+4m outer dia=(100-(4*.15))=99.40mt dia
+4m inner dia=(99.40-2*0.5(wall thickness)=98.40mt dia
chimney 90degree maintain =center point maintain 0 to 120mt&
check radius every +1mt
| Is This Answer Correct ? | 2 Yes | 0 No |
Answer / omkar
example:
bottom outer dia=100mt top outer dia =82mt height=120mt wall
thickness=0.5mt
(100-82)/120=0.15mt each 1mt reduce the dia 0.15mt ok
+4m outer dia=(100-(4*.15))=99.40mt dia
+4m inner dia=(99.40-2*0.5(wall thickness)=98.40mt dia
chimney 90degree maintain =center point maintain 0 to 120mt&
check radius every +1mtĀ
| Is This Answer Correct ? | 1 Yes | 1 No |
What is the dimension of Slump cone which is used to measure the Slump value of concrete? Slump value for Pile concrete? Slab concrete? Column concrete?
what is the detention period for oxidation ponds
sir iam dng my engg final yr (civil) iam intrested to write group_1 .if we write this exam what kind of jobs we get and what should be the minimum score for us to get qualified and iam having reservation too.
Hi is it any equation or relationship that describe the stress-strain diagram in concrete deep beam?
What are the types of ladders?
where should the lap of a beam should be
how to determine the correctness of proportion used in cement mortor and various IS codes to determine the same?
What is cutting Length of stirrups of a beam 300mm*300mm.
What is the size of your cube mould
how to design a formwork for beam, how to determine the load baring capacity of the cuplock system and which is the relevant code for the same.
how do i remedy a foundatiom that the column bases was cast and aftet 28days crushing the conprehensive strength of the concrete fall below the specification 25N/mm2
SAND AND STONE AGGREGATES WASTAGE PERCENTAGE IN CONCRETING WORK?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)