Answer / pandiyan.m
singly reinforced beam is reinforced at tension zone alone
and doubly reinforced beam is reinforced at both zones and
difference is singiy cannot take too much loads
Is This Answer Correct ? | 37 Yes | 4 No |
Answer / himel
when rf is reqd in only tensile zone of beam, its called
singly rc beam, when moment is large enough is to reqd to
provide rf at compression zone also,called douly rc beam.
load variation is the only difference betn these two.
Is This Answer Correct ? | 14 Yes | 2 No |
Answer / kamal pandey
single rc beam is reinforced at tension zone only and doubly
rc beam is reinforced at comperesion & tension
zone.difference is singly cannot take too much loads
Is This Answer Correct ? | 7 Yes | 1 No |
In singly reinforced beam limiting moment of resistance is higher than design moment. And the reinforcement designed for tension zone only.
In doubly reinforced beam limiting moment of resistance is lower than design moment. And the reinforcement designed for both tension zone and compression zone.
Is This Answer Correct ? | 7 Yes | 2 No |
Answer / desai ankit
In singly rc beam,reinforcement is provided on tension side only.While in doubly rc beam ,reinforcement is provided on compression
Is This Answer Correct ? | 0 Yes | 1 No |
Answer / anil kumar
singly rc beam is defined as in which single bent up bar is
used & doubly rc beams may be defined as in which two or
three bent up bar are used are termed doubly reinforced beam
Is This Answer Correct ? | 1 Yes | 10 No |
How do you compute moisture correction using the parameters gathered from Nuclear Density Gauge Apparatus and the moisture contents results from the lab.?
how to find quantity for binding wire steel.
Anyone have sample questions for bhel please send me since Iam appearing for this exam. Kindly send this to my e-mail: nethaj_babu@yahoo.co.in
Should column area deducted from form work measurement of slab in building?
what is diff between auto level and dumpy level?
I HAVE APPLIED FOR 20TH UES ARMY. I WANTED TO KNOW WHEN WILL I RECEIVE CALL LETTER FOR THE SAME.
What is logic behind the use of Steel bar insted of gold bar?
what is the length of a steel bar when it buy for the site????
What expenses counted in contingencies and how much it is in related to built-up area of the building.
is there any difference in footing and slab reinforcement?
briefly describe your ideal job?
Define relative co-ordinates?