Why all voltage level are multiples of 11, like 220V, 440V,
1100V instead of 200V, 400V, 1000V?

Answers were Sorted based on User's Feedback



Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of 200V, 400V, 1000V?..

Answer / bikash

since all the voltage generation are in average and we use
rms quantities for computation. so we need to convert the
average to rms simply by multiplying the form factor 1.11.
thats how the voltage levels are in the multiple of 11.

Is This Answer Correct ?    56 Yes 8 No

Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of 200V, 400V, 1000V?..

Answer / thunder bird

AC voltages are sinusoidal in propagation. the electrical machines are designed for root mean square(RMS) values of voltage which is nothing but equivalent D.C voltage.whereas insulation, transmission etc are calculated for average(AVG) values which is 1.1 times RMS value.1.1 is form factor for sinusoidal waves. (form factor = RMS value/ AVG value). so a generator may be producing 400 kV RMS but in common mans' term it will be 440kV.

Is This Answer Correct ?    4 Yes 3 No

Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of 200V, 400V, 1000V?..

Answer / girish

AC sine wave form factor will be of RMS value / Average value
of a sine wave, that will be 1.11, so all voltage levels are
multiples of 11

Is This Answer Correct ?    4 Yes 4 No

Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of 200V, 400V, 1000V?..

Answer / sakthi

its a historical reason. initial days design people assumed that line losses will be around 10%. so they have designed to 110% to get 100%. but nowadays it has been changed. now we are using 400V instead of before 440V. 230V instead of 220V before. There is nothing to do with form factor. its not involving any of the design calculations.

Is This Answer Correct ?    3 Yes 3 No

Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of 200V, 400V, 1000V?..

Answer / cheech

just for shits & giggles

Is This Answer Correct ?    2 Yes 2 No

Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of 200V, 400V, 1000V?..

Answer / mohamed

We are designed the alternators windings should be wound '11o' clock position.

Is This Answer Correct ?    0 Yes 3 No

Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of 200V, 400V, 1000V?..

Answer / sreeknp

when converting average value to r m s multiplication factor
is 1.11 hence voltages

Is This Answer Correct ?    4 Yes 8 No

Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of 200V, 400V, 1000V?..

Answer / aks

we don't now. Mr.MD.Shahnawaz pls tell the correct answer.

Is This Answer Correct ?    2 Yes 13 No

Why all voltage level are multiples of 11, like 220V, 440V, 1100V instead of 200V, 400V, 1000V?..

Answer / sundeep

Because anywhere the generator rating is 11kv...so the
voltages are stepped up or stepped down in the multiples of
11...

Is This Answer Correct ?    3 Yes 16 No

Post New Answer

More Electrical Engineering Interview Questions

how synchronous generator can be used as synchronous condenser?

3 Answers   Monnet, Wipro,


what is the eight bit unit?

0 Answers  


The error in a single phase energy meter where pressure coil lags behind applied voltage by 88 degrees and pf is 1) upf 2).5lag

1 Answers   GATE,


When semiconductor fuse does save thyristor in each cycle of conduction? Why under voltage setting keep less in SPRS and more in DC drive?

0 Answers  


What is highest size of HT motor like 11 kv or 33 kv,and how to make it 750 rpm.i think the size will be very big.any idea ? pl. reply..

0 Answers   ABB,






What does the term “voltage regulation” means?

0 Answers  


what is the effect of vector group while phase sequence of a generator changes,whether the vector group changes or not

0 Answers  


what is the difference between id fans and fd fans

12 Answers   Perkins Thermal Systems,


State and define norton’s theorem?

0 Answers  


what purose of the double circuit transmission line phase of the line phase changed for circuit-1 for Circuit-2 R-Y-B B-Y-R

0 Answers   NCC,


what is the pre charge circuit,what will be work which function it will be use plz tell me

0 Answers  


What is the need of black rock stones under the transformer yard?

5 Answers   TNEB Tamil Nadu Electricity Board,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)