Why all voltage level are multiples of 11, like 220V, 440V,
1100V instead of 200V, 400V, 1000V?
Answer Posted / aks
we don't now. Mr.MD.Shahnawaz pls tell the correct answer.
| Is This Answer Correct ? | 2 Yes | 13 No |
Post New Answer View All Answers
In vapour absorption refrigeration machine fluids used are
How do apply electrical 'c'license......pls advice
An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?
WHAT IS DEGREE OF COMPOUNDING IN D.C MACHINE MEANS? HOW TO READ THE OPERATING CHART FOR ANY ELECTRICAL MACHINES?
what is the use of the circle diagram
What is reactance, reluctance,capistance, pls give answeer in hinglish and be simply Jo asani we smajh m aa jaye
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
How we can calculate the consumption in kwh of motor on basis of kw @100% load, @50% load & @ no load.
when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you
what is the standard duration after failure EB power
Cb closed condition if there is a tcs fail whether cb will trip or not
How to decide whether A / B / C / D curve type MCB should be used?
How to know th details about an electrical Drawing ? Please mention the easy method.
After doubling voltage from solar cells & use step down voltage transformer can we get high current output with low voltage.
what is the effect of power factor of machines in starting current