Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

why would the rotor rotate at sub synchronous speed against the direction of rotating flux when d rotor of 3 phase IM is connected to 3 phase balanced supply and the stator windings are shortcircuited ??

2100

How much UG cable size should i use so as to accomodate a ground + 2floors house. A 1.5ton AC & geysers(2) in each floor with lightings

2 4462

which strater used genearalyy???and why???

1 3651

There are 2 motors without name plate and terminal but one is DC motor and another is induction motor.How one can identify which one is DC and which one is AC motor?

6 12490

in india per day how much power is generated including all power station

2030

what is the job description of a LOW CURRENT ELECTRCIAL ENGINEER in a industry?

BTAT, Powercraft, Prince Glass, Sterling,

1 16356

How to Design green buildings services? What is the advantage to design green building?

1859

How the flights will be fly be fly without ground connection under raining with thunder lighting?

1 3484

how the transformer stables out zone faults? Because we use non directional O/C relays .Is there any special considerations are taking into account to overtake this?

1 3135

why it is necessary to short and ground of a current transformer secondary side?

Ambuja,

6 9710

The electrical energy required to raise the tempreture of a given amount water is 200 kwh. If the heat losses are 20%, the energy required is?

2074

How to findout raw or ups power? its not indicated in socket,

Novo Nordisk,

2093

Why smallest capacity LV motor are star connected and medium & bigger size LV motors are delts connected

1 3068

why induction motor takes high current?

Emerson,

1 7061

In 11kv transmission line whats the maximum power can be drawn?

Concast, Prestige,

1 6005


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

is that any software calculator to calculate the size of cable

2399


How can we increase fuel-power ratio of any DG set?

1862


UG cable sizes were specified in sqmm. But practically its not coming to mesure. What's the reason for that? And how they specify the size of the cable?

1978


What are the Return ( Monthly / quarterly/ Annual submitted to Electical Inspector for an establishment (Factory in Maharashtra-- Small scale category having seperate HT line of 22KV ) as per Maharashtra Electricity Act

2088


plese send me the oces/dgfs sylabus and previous year question pattern of electrical engg.?

2358


can i use the six sigma method which is used in management area, in state estimation of power systems?

1910


Why can't we take NO LOAD TRIAL of motors having V1 mounting??

1984


what is the difference between interconnection and intraconnections in the circuit diagrams

8468


What is method of calculating the fault current for a MDB, 50KW, 3PH, 415V, 50HZ?

2188


In India the supply voltage is 230 volt A.C. During the negative half cycle phase becomes neutral and neutral become phase? or what will happen during negative half cycle? how the electrons flow during positive and negative half cycle?

2089


How does a tertiary winding filter harmonic(espcially 3rd one) from entering into load system?

1869


What is cathode ray oscilloscope (cro)?

1173


PAC and simple Ac different

1571


why do we put a transformer on soak before loading it

1196


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2211