Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a campus site?

2 5120

If the ceiling fan is on slow speed, does it consume less electricity?

2 9291

If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?

Focus,

2 9437

What is maximum AC & DC transmission voltage in India? and where?

12 37753

why we get 2 differnet values for power factor in 2 watt meter method in 3 phase

1867

what is the resultant phase shift in a 3 phase power system including neutral if on or more phases gets grounded or short circuited. kindly explain in detail for the reasons...

Enercon,

1 5848

what is the radio of kva & kvar or why calculated kva & kvar

3 6358

Why inverter rating in KVA?

3 18054

is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?

1872

what is cascade speed control device?and how this device control the speed of motors?

ABB,

2178

If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?

Focus,

1 4869

When do you use a VFD motor?

3 6925

How many 2 ton window A/c can runs on a 125 KVA generator?

7 32372

Why tripping not occur when the transmission breaks? Doesn't we provide earthfault protection for it?

1 3443

What is Bolted fault?

2223


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?WHAT IS THE NEED TO BE PHASE SHIFT CHANGE BETWEEN THE PRIMARY AND SECONDARY WINDING

1802


what are factors to be consider to design a HT & LT motor?

2335


I am EEE student i want to improve my core side skills.how cn i approach it?

2537


What is the main use of rotary phase converter ?

1166


How to calculate the fuel consumption for 600kva DG genset which connecting with 25%load?

2139


Why is a synchronous motor always star connected??

2623


Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?

1997


Dear all, how we select the cable size according  to current with or without including different correction factor , is there any direct method for sizing of cable... 

2181


hi,every one, i have to write the search paper on "performance policy optimization" of NGN (next generation networks). i need the material on this topic. can any body help me. please tell me any useful site where the good material is available and name of any reference book. it should be a great help for me.

1932


Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar

1842


Why synchronous motor is used in power factor improvement,dc series in lift

1679


What is the different types of cable & current capacity of cable

1979


how many current required for hypo test

1987


Who are the manufacturer for Nitrogen based Fire Protectio/explosion prevention for Oil Filled Transformers? India and international both?

1935


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

2231