If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a campus site?
2 5120If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?
2 9437what is the resultant phase shift in a 3 phase power system including neutral if on or more phases gets grounded or short circuited. kindly explain in detail for the reasons...
1 5848is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?
1872If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?
1 4869Why tripping not occur when the transmission breaks? Doesn't we provide earthfault protection for it?
1 3443Post New Electrical Engineering Questions
WHAT IS THE SIGNIFICANCE OF VECTOR GROUPS IN TRANSFORMER? WHAT WILL BE EFFECT WHEN PHASE DISPLACEMENT CHANGES IN TRANSFORMER?WHAT IS THE NEED TO BE PHASE SHIFT CHANGE BETWEEN THE PRIMARY AND SECONDARY WINDING
what are factors to be consider to design a HT & LT motor?
I am EEE student i want to improve my core side skills.how cn i approach it?
What is the main use of rotary phase converter ?
How to calculate the fuel consumption for 600kva DG genset which connecting with 25%load?
Why is a synchronous motor always star connected??
Is there any problem about which the drive (inverter) doesn't show/display the alarm and/or fault but instead of this , it doesn't work ? I want to know that could there be any kind of problem in the drive when the drive doesn't display the alarm and/or fault ?
Dear all, how we select the cable size according to current with or without including different correction factor , is there any direct method for sizing of cable...
hi,every one, i have to write the search paper on "performance policy optimization" of NGN (next generation networks). i need the material on this topic. can any body help me. please tell me any useful site where the good material is available and name of any reference book. it should be a great help for me.
Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar
Why synchronous motor is used in power factor improvement,dc series in lift
What is the different types of cable & current capacity of cable
how many current required for hypo test
Who are the manufacturer for Nitrogen based Fire Protectio/explosion prevention for Oil Filled Transformers? India and international both?
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.