1 2279How do we measure earth fault current in Generator Transformer(20/420kv),Station Transformer(20/11 kv) and Unit Transformers(20/11kv) for our plant system, since these don't have any Neutral earth Fault relay connected to their Neutral Earth? But for Unit Service transformers(11/.433 Kv) we have an Earth Fault Relay connected to its neutral earth.Why is such so?
NTPC,
1 4412A 230V dc shunt wound motor has an armature resistance of 0,15Ω.When operating on no load at 650 rev/min the armature current is 6A . The motor takes a full load current of 85A. Calculate the full load speed if the field flux is (i) maintained constant (ii)reduced by 0,03
1790ITI r/tv trade APPLY (J.T.O VACANCEY) ALSO INCLUD AITT ELECTRONIC,WRITEEN XAM DONE 23.03.10 BUT NO RESPONCE WHY ANATHER ID gopal_gh007@rediffmail.com
3168why voltage form factor of PT are increase , when it is ecpected heigher spikes in system. how it is calculated.
HAL,
1890what is the difference between the following 2 situations ? 1)Line & Neutral=240V Line & Earth=230V Neutral & Earth=10V 2)Line & Neutral=230V Line & Earth=240V Neutral & Earth=10V
2 6141What is the effect on power factor, shown by a trivector meter; incase of reverse phase sequence. If the power factor of a system is lag what meter will show in case of reverse phase sequence connected to the meter. and What in case of lead.
TATA,
2072Post New Electrical Engineering Questions
how we findout a ignater is faulty or not?
Bimetal strip used in overload relay what is that,which types of material used for that & percentage.
what can be the causes of capacitor start motor having a higher current that its actual
what is meant by skew width in machines?
what happens when series resonance occurs?
how can get electrical "c" licence.i am complited in DEEE.PASSING YEAR OF 1993.WORKING IN PVT COCERN LT LINE.PLEASE ADVISE ME .CELL NO 9994786021
what is the standard values(Megger test) of resistances between L&N,L&E and N&E for a system on IEE regulations?
In EHV transmission line a neutral grounding reactor is often placed at neutral point of shunt reactors. What is the recommended protection for this neutral grounding reactor? Should I use a fast closing switch to bypass neutral grounding reactor when this protection operates?
how we can decide that what value of ht line will come to any commercial building? (ans except According to the building load)
what is advertised hop count
How many types of protection relays are there based on the characteristic?
what is the solution for meger test failed the MV cable?
why we use sinosidal voltage / current instead of others in system?
What is load boxes ?
what is the meaning of 5% droop or 7% droop in AVR?