Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

On what principle reluctance motors work?

1 3978

What is the difference between magnetic loading and electric loading of a machine?

2 36619

How the size of electic machine vary with the sped? Between slow and fast running machines of equal ratings, which one is more economical to design?

1 3491

what is the relation between frequency and inductive reactance in a d.c supply?

L&T,

2 7018

Why machines are avoided to work is saturation region of B- H curve?

3 5867

Why different values of B’s (magnetic flux density) are chosen for DC machines and Induction Motors?

1 3223

How the output,losses and temperature of machines varies with linear dimension?

1 4892

Why air gap in rotating machines should be small?

3 7839

Why rotating machines are not allowed to run near critical speed region?

2 6604

From stability point of view,What(higher/lower) should be the value of inertia constant of rotating machines?

1 3791

how to reduce humming noise in transformer?

3 10241

There are two nos of 33Kv/11Kv 5MVA transformers conecting through HT cable from substation having metering at substation itself.One transformer used at a time another remains stand by.Further 11 nos of 11Kv/440V transformers are attached on it and each transformer is having its own Power factor correction panel.Now one 33/11Kv transformer at no load condition/Stand by condition is having power factor in leading side upto 0.21 and while when another tranformer at same situation have power factor in lagging 0.42. Now one thing is clear that transformer one is having 1.5 Km long 33kv cable due to that PF goes in leading side and another is having only 250 mtr length remains him lagging. Now i want to know that how i can maintain the Power factor at no load/ stand by position though both are behaving in seperate manner.

1 6750

Why oil preferred over the air as a cooling medium for high rated transformer?

1 4366

What is emperical relation.Name few of them which are used in electriacl engineering?

1 4166

In the ACB breaker capacity is 2000Amp but this each phase taken 1250 But total beldibg load is 600amp or 700amp watt is the problem

1964


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Is it possible to connect a safety device in to parallel?

2153


How to size fuse? How to size MCB?

1521


WHat is the general checks required for Dry type transformers

2083


why transformer tank is in rectangular shape what happen when it is in step shape

1454


how give earthing conection to household equipment?

2038


can any one suggest me the tilt angle of my solar pannel ?? or tell me how can i know the fix tilt angle of my solar pannel?? my cordinates are 31.503629,72.993164.

1812


How to calculate the time setting for star connection in star delta starter? For example 10KW 3PH Induction motor.

2625


12.5 tons a/c is their how much kva generator can recommend to the customer.

2030


what is the safe meggar values for motor, transformer HT, LT and Cables? IF we want to replace I/C bay at our 220 kv substation which is of 140 mw load capacity bay to be replaced by 400 mw capacity bay.other than CT(1200/1) what are the other equipment i have to replace. why we generally use 3.5 core cable or in other word 1/2 core for neutral and also confirm me that in balance conditiob(3 phase)current in neutral will zero

2273


how we can decide that what value of ht line will come to any commercial building? (ans except According to the building load)

1662


what is RFCT and Insulgard Relay & It's function?

2191


Why do we need interlocking in a HT metering or Ring main unit switchgear?

2023


What is meant by earthhing of a magnetic flow meter and when to use empty pipe detection?

2239


what is efficient motors and how it is different from normal induction motors

1913


1.how many earth pits are required for 1000 k.w plant include substion , transformer ? 2. how many earth pits are required for 500kva generator.what is formula to calcute?

2916