Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

Pls tell me whether we can use EN3A material for shafts of Permanent magnet alternator.What will be the effect of magnetic and nonmagnetic material for shafts on magnetic properties of PM rotor .

3457

what is reactive poower

3 5174

directional relay is typically used to respond in fault condition who it can be used just as reverse power protection which purely senes direction reversal to operate a circuit breaker?

1 3922

I have carried out wiring for lighting in a shed in Industrial area which contains Metal halide lamps & have balanced in 3ph.Now when we put all the lines on in the daytime the current taken at 3phases at MCB comes to be equal i.e.28,29,28Amps respectively but in the night time i.e between 7p.m.to 11p.m. at the same MCb the current is 52,59,62Amp, though I have fit 63A MCB it is tripping in the above period.What may be the reason.? Note: This industry is located in industrial area where majority of steel ingot manufacturing plants are there. Whether this may be due to harmonic? what should I do to overcome above problem.pl suggest urgently.

4 6498

is oil viscosity affect on motor current?

1964

If I want to replace a 26KW Slip ring Motor with a Squirrel Cage motor & Drive (for a Hoist Application). How can I approximate the Motor & Drive HP required in new Setup.

2226

Why does the Solid state Rectifiers for 3-ph brake motors sometimes have 2 & sometimes 3 output terminals?

2061

How two nos. 130 kw D.C motor get synchronise using D.C drive.

2076

what is slip rings in an induction motor&what is it's work.

4 7601

how to test the turn ratio of 3 phase transformer using volt meter shoe the curcit diagram.

2394

what is the reqirred voltage in HT motor to get full RPM on no load test?

2016

Why OLTC(On Load Tap Changing)transformer is not recomended for improving voltage instability?

2 6203

which site/city in India has all three(thremal,Hydal and Nuclear)power generaton facilities?

2 5134

Why generating voltage is limited up to 22kV?

4 7594

1. A bomber drops a bomb from an aircraft flying at 2000 km/hr. at an altitude of 7km. The speed at which the bomb will strike the earth would be

KNJ,

1876


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

What is “pu” in ee?

1032


what is the effect of back reactive power on the generator ?

2172


is there any chart showing the suitable cable size according to AMP and length ? for three phase motors

1366


ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?

1981


Post possible questions for Power Factor Panel FAT / SAT

1370


why sometime we get electrical shock while touching the ballon of dish tv connection ? which we should not get.

1960


At full load wat is the motor p.f And at no load will is the motor p.f?

2085


I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?

1708


use of choke in APFC panels

5736


what is maxemo work permit procedure

2167


if we look on phasor of the transformer vaoltage is 180 oppsite at primary and the secondary so to improve a power factor is secondary should kept negative to improve it primary side means is -.90 became +.90 at other side

1835


give some advantages and disadvantages of combiniing the session, presentation, and application layer in the osi model into one single application layer in the internet model

2664


sugest any typical project ?

1770


DESCRIBEPNEUMATIC SYSTM OF ASH HANDLING PLANT

5486


how we decide the require size is this for a known current at fuu load?

1926