How we can differniate the overhead lines feeded by hydro power stations & thermal power stations
1 3651We have a 12MW power plant & we inject 5-6MW power to Orissa GRID. For this we have a 33KV/11KV switch yard having 12.5MVA power transformer. Some times we draw power during emergency. It is observed that during Export or Import for load less than 500Kw the power factor is decreasing to 0.3 . This is happening only during export or import. During island condition TG power factor OK.Our capacitor bank is provided with our Power plant auxilliary load. Please suggest how I can we improve our power factor during low load (GRID).
3 67211.main parts of generator? what is used A-check,B-check,C- check? 2.what is FM200 system in data centers? 3.difference between pac,ahu?
TATA,
2131What is the real use of reactive power in a electrical system other than loss (inductive &capacitive).I want to know its real physical significance.
1831What happen to the transformer if the OLTC frequently used for lower and raise occured 50times daily?
2050what is the purpose of the armored for the power Or control cable? How to select the type of the armored?
1 4380what are the types of starter ?
Andhra Sugars, Bhel, Eveready, HyFun Foods, Jindal, ME, Valeo Lighting Systems India Private Limited,
25 192866can a generator with 15AH specified battery for starting can be connected to a battery of greater capacity?
2 3966Post New Electrical Engineering Questions
what will happen if the prime mover on the field excitation of the on-coming generator fails?Explain.
why does the magnetic balance tests at transformer?
What kind of preventive maintenance are there for transformer?
DG cranking voltage?
HOW THE OLTC TRANSFORMER SAVE ENERGY IN COMPARISON TO OFF LINE TRANSFORMER AND IS IT ECONOMICAL TO REPLACE THE OFF LINE TRANSFORMER TO OLTC TRANSFORMER
What is the need of generator relay panel
what is the difference between directional & non directional earth fault with example please explain.
how we provide neutral earth on synchronising panel as per electrical standards?
What is the comparison between 30mA DP RCCB and 100mA DP RCCB and can replace it against 63A MCB
Why 30kw 40 hp 4 pole 3ph induction motor over heated?any steps on reduction in heat?
sir iam from electrical and electronics branch ,can i appear for the hpcl offline requirtment? if yes please mail me on vikram_raju25@yahoo.co.in
why should the primary of transformer be connected in delta in a heat run test?
What is the effect of atmospheric pressure & Temp; on efficiency of motor? Why NGR(Neutral Grounding Resistor) is used in 132/11 KV Transformer & how? What is the use of Auto T/F in Grid Station?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
How can we choose the rating of submersible motors