HAI,I HAVE 6,60KW MOTOR FEEDERS IN MY MCC PANEL.HOW CAN I DO MY SETTINGS FOR OVERLOAD,SHORTCIRCUIT,GROUNGFAULT,INSTANTANEOUS TRIP FUNCTION IN MY 4000A CIRCUIT BREAKER?
1 3899I have 500A load (WHICH IS SEPARATE MDP PANEL),an MCC panel with 4000A Breaker.Already I have 2500A load.Can I connect this load directly to the Busbar since I have PROTECTION IN MY MDP Panel ?
4 7915During the troubleshooting of an inoperative shunt generator, you found the voltage to be 2+ volts; what is known from this. Is it (1). odds are the armature is good (2). odds are there is no field current flowing in field windings (3). odds are the armature is bad (4). both 1 & 2 are correct (5). both 2 & 3 are correct
2 5921We are having a 2000KVA DG set. It trips with Over speed and Engne Hot when the mahine is stopped in full speed. How shall I analyse the block load and reverse power.Is the problem related to power factor. The machine which runs on this DG is having all Synchronous motors with incividual Drives.
1 3850how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.
ONGC,
2352why various test are performed on electrical panels & power cables before commissioning on site & what are these test???
1946I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?
3771sir please send me iocl written test paper in my e-mail account. i'll be obliged to you........ thank u roshan
IOCL,
2178Post New Electrical Engineering Questions
Could the power factor on electrical system can affect the registration of the kwhr meter or the CT/PT?
what will happen if multimeter(selector switch at DC voltage) and terminal at current is connected to DC supply?
What is the best thing to protect the motor from running over full current. CT or O/L or pressure transducer at the given pressure rating
IN induction motor pf is increased using capacitors.what will be the effect on motor and system when very large capacitor is accidently installed and pf goes leading.
What will happend if given Vfd out put to step up transformer
why we testing the core balance of the transformer before comissioning?
what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....
difference between the applicability of nortons and thevenin theorem
What is stepper motor?
whats the application of voltage regulation? and whats the voltage regulation's device?
Explain about p.t?
What is a Phase shift meter? Where can I get one?
If one tertiary phase i.e. R,Y or B is earthed of a loaded type tertiary delta connected (Without load)of a power auto transformer, what is its advantage/disadvantage?
How to address the servo drive for motor
what is sevice settings for mccb?How can be it setted?