HAI,I HAVE 6,60KW MOTOR FEEDERS IN MY MCC PANEL.HOW CAN I DO MY SETTINGS FOR OVERLOAD,SHORTCIRCUIT,GROUNGFAULT,INSTANTANEOUS TRIP FUNCTION IN MY 4000A CIRCUIT BREAKER?
1 3981I have 500A load (WHICH IS SEPARATE MDP PANEL),an MCC panel with 4000A Breaker.Already I have 2500A load.Can I connect this load directly to the Busbar since I have PROTECTION IN MY MDP Panel ?
4 8061During the troubleshooting of an inoperative shunt generator, you found the voltage to be 2+ volts; what is known from this. Is it (1). odds are the armature is good (2). odds are there is no field current flowing in field windings (3). odds are the armature is bad (4). both 1 & 2 are correct (5). both 2 & 3 are correct
2 6038We are having a 2000KVA DG set. It trips with Over speed and Engne Hot when the mahine is stopped in full speed. How shall I analyse the block load and reverse power.Is the problem related to power factor. The machine which runs on this DG is having all Synchronous motors with incividual Drives.
1 3921how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.
ONGC,
2386why various test are performed on electrical panels & power cables before commissioning on site & what are these test???
1997I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?
3811sir please send me iocl written test paper in my e-mail account. i'll be obliged to you........ thank u roshan
IOCL,
2214Post New Electrical Engineering Questions
i need to now what will be the cable size to the following load, transformer to distribution panel distance 110m, load 1000kw, voltage 400v, pf 0.85, permissible voltage drop 2.0%, overhead line, atmospheric temperature 35 degree c.
Define damping ratio.
Difference of induction motor & servo motor ??
how to decide the capacity of accl
how do we calculate length of starting time and repeated starting of a direct online starter?
In all analog voltmeters or ammeter showing some small size symbols. as well as a star and in star 2no. digit, resister symbol,and other. what is that's meaning ?
can u give me a brief idea about power line carrier communication ??
how i chosse capacitor bank if my energy meter is 48 kvr? tell me capacitor bank chossen formula?
Why collecting electrode of ESP to be earthed
What is Meter MF if External CT Ratio is 150/1 , PT Ratio is 132/110 Meter CT Ratio is 200/1 & Meter PT Ratio is 110/1
what is self capacitance of inductor
what is the purpose of using filters in a protective relaying scheme?
where can the transformer having vector group Yny0 be used??
What is the difference between acs 550 & acs 850
during installation time of transformer and alternator which points we have to observed?