Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

HAI,HOW TO SET THERMAL OVERLOAD RELAY FOR DOL STATRTER FEEDER AT START AND RUNNING?

L&T,

4 15302

HAI,I HAVE 6,60KW MOTOR FEEDERS IN MY MCC PANEL.HOW CAN I DO MY SETTINGS FOR OVERLOAD,SHORTCIRCUIT,GROUNGFAULT,INSTANTANEOUS TRIP FUNCTION IN MY 4000A CIRCUIT BREAKER?

1 3899

What power factor maintain you maintain at u r organisation

Wheels India,

14 20594

I have 500A load (WHICH IS SEPARATE MDP PANEL),an MCC panel with 4000A Breaker.Already I have 2500A load.Can I connect this load directly to the Busbar since I have PROTECTION IN MY MDP Panel ?

4 7915

During the troubleshooting of an inoperative shunt generator, you found the voltage to be 2+ volts; what is known from this. Is it (1). odds are the armature is good (2). odds are there is no field current flowing in field windings (3). odds are the armature is bad (4). both 1 & 2 are correct (5). both 2 & 3 are correct

Air Force,

2 5921

We are having a 2000KVA DG set. It trips with Over speed and Engne Hot when the mahine is stopped in full speed. How shall I analyse the block load and reverse power.Is the problem related to power factor. The machine which runs on this DG is having all Synchronous motors with incividual Drives.

1 3850

how to calulate bearing number of any motor ?

Transfield,

1869

how we can find of current direction(supply comming/out going direction) when a transmission line passing through sides.

ONGC,

2352

why various test are performed on electrical panels & power cables before commissioning on site & what are these test???

Lavasa,

1946

I have 2500KVA transformer delta/star,13.8KV/380V provided with LV 4000A breaker. Already I have 2300KW motor feeder with a full load 90%. Is it possible to connect another 1600A from that breaker? If so how the calculation is done?

3771

sir please send me iocl written test paper in my e-mail account. i'll be obliged to you........ thank u roshan

IOCL,

2178

what is the significance of KV & MVA rating of the transformer and how they are related.

8 83023

what is the permissible bend in the LT& HT CABLES.

2 5723

WHAT KIND OF LIGHTENING PROTECTION SCHEMS CAN BE ADOPTED FOR THE FLAT ROOF OF BIG DIMENSION.

2089

WHAT IS DGA TEST FOR THE TRANSFORMERS.

ABB,

3 19805


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

Could the power factor on electrical system can affect the registration of the kwhr meter or the CT/PT? 

1908


what will happen if multimeter(selector switch at DC voltage) and terminal at current is connected to DC supply?

1927


What is the best thing to protect the motor from running over full current. CT or O/L or pressure transducer at the given pressure rating

1496


IN induction motor pf is increased using capacitors.what will be the effect on motor and system when very large capacitor is accidently installed and pf goes leading.

2094


What will happend if given Vfd out put to step up transformer

1772


why we testing the core balance of the transformer before comissioning?

2127


what is the generator rating for 40 amp load of 3phase motor.?? 400v voltage of generator... plz tell me with formula its urgent...plzzz... and also tell me that this 40 amp at all phases mean 40 amp on red,40 amp on yellow,40 amp on blue...... or the total sum of that 3phase is 40 amp....

9014


difference between the applicability of nortons and thevenin theorem

2045


What is stepper motor?

1234


whats the application of voltage regulation? and whats the voltage regulation's device?

1848


Explain about p.t?

1047


What is a Phase shift meter? Where can I get one?

2187


If one tertiary phase i.e. R,Y or B is earthed of a loaded type tertiary delta connected (Without load)of a power auto transformer, what is its advantage/disadvantage?

2037


How to address the servo drive for motor

1962


what is sevice settings for mccb?How can be it setted?

1938