Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...



Engineering Interview Questions
Questions Answers Views Company eMail

can any one tell eligibility criteria (percentage of 10th,12th & b.tech) for IES & RRB ?

UPSC,

3 9397

which one is dangerous AC Power r DC Power for Electrical Shock ?

10 13189

what is recovery voltage & transient voltage ?

Bhel,

1 4718

what is ferranti effect?

3 8007

what is skin effect?

4 7734

what is full form of caesar-2 for piping engg.

5 20981

why circuit breaker closing time is always higher then tripping / opening time.

United Phosphorus,

13 48641

what is transformer

Aegis,

5 9590

How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?

4491

how rating of transformer is selected for any new plant/what kind of load is cosidered/what kind of fadtors are considered/ pz give standard procedure

2 4765

why colour of electrical equipment( like transformer) is grey

Trident,

10 38652

what is differance between PLC and Logic Card?

3 18761

what is the relation between voltage & frequency

11 60802

What are the lubricating system of an IC engine?

9 16387

What are the procedures of starting of diesel engine?

Covanta Energy,

2075


Un-Answered Questions { Engineering }

whan type of controller is used in power plant?

2186


What is a schmitt trigger?

1143


The number of columns in a state table for a sequential circuit with m flip-flops and n inputs is

1388


Write the analogous electrical elements in force voltage analogy for the elements of mechanical translational system.

1363


How to derive detailed design of Suitable bus Bar for 100A for 6.6KV?

1826


TRAFO 1. WHY BREATHER IS USED. 2. WHY OIL GOES DOWN IN CONSERVATOR TANK. 3. WHY WE ARE TAKING OIL SAMPLE TAKING FROM BOTTOM OF TRANSFORMER. 4. HOW TO CHECK IR VALUE OF TRANSFORMER. 5. WHY OLTC HAVING BUCHHOLZ TRIP ONLY; WHY NO ALARM. 6. OFF LOAD TAP CHANGER OPERATION PROCEDURE. 7. TR. SHUTDOWN / ISOLATION PROCEDURE. 8. WHEN THREE TRS. IN PARALLEL, ONE TR. IS NOT SHARING THE LOAD – WHAT IS REASON AND WHAT YOU WILL DO. 9. WHY TR. HAS OLTC IN HV SIDE. 10. WHAT IS % IMPEDANCE. 11. WHY TR. RATING IN MVA. 12. WHAT IS VECTOR GROUP IN TR. 13. CONDITION FOR PARALLEL OPERATION OF TRS. 14. WHAT IS TERTIARY WINDING. WHERE IT WILL BE. 15. IF TR. TRIP ON BUCHHOLZ OR TAP CHANGER RELAY, WHAT YOU WILL DO. 16. DIFFERENCE BETWEEN OIL TEMP. AND WINDING TEMP. PROTECTION 17. HOW WINDING TEMP. IS MEASURED IN CAST RESIN TR. 18. DIFFERENT TYPES OF FAULTS IN TR. Trafo - Page-1 of 2 19. WHAT HAPPENS WHEN TR. CHARGED FROM LV. 20. WHAT WILL YOU DO IF MEGGER READING SHOWS ZERO BETWEEN LV WINDING AND EARTH. 21. CAN WE INTERCHANGE BUCHHOLZ RELAY OF MAIN TANK AND OLTC TANK. 22. IF THE LINE BETWEEN BREATHER AND CONSERVATOR TANK 23. LOCKED, WHAT WILL HAPPEN DURING LOAD CYCLE. 24. WHAT IS THE FUNCTION OF OIL SEAL IN BREATHER. 25. WHAT ARE LOCATIONS FOR BUCHHOLZ RELAY FIXED IN POWER TR. 26. WHAT ARE CHECKS IN POWER TR. DURING MAINTENANCE. 27. WHAT IS IMPORTANT WHEN WE CHECK OLTC OPERATION DURING MAINTENANCE. Trafo - Page 2 of 2

2410


WHY BLADE & JOW OF ISOLETOR IN SUBSTATION?

5071


What is time response of the control system?

1108


i want to know some description about SIM architecture... what is inside the SIM?

1944


Explain Consumer buying behavior ?

5


What is depreciation factor?

2284


how to calculate the tarriff for an industry whose kva demand is 10 mva

2001


what is the class of generator A b & c

1640


MY generator water cooler inlet line height - 11 mtr inlet water line height - 7 mtr water come into the line from overhead tank, O/H tank height - 20 mtr the first tapping in the inlet line is 2" line which down to 4 mtr level plateform., second tapping in inlet water line goes to a pump 6" line installed at 4 mtr level plateform, pump capacity 200m3/hr, head- 30 mtr, hp-40. the outlet of pump of 6" water line connected to a header of 6 mtr long of 6" line, on this header the six tapping are connected, 4 nos. 3" line goes to 11 mtr height water cooler the pressure of the line is 0.15 to 0.25 kg/cm2, 2" and 4" pipe line connected to a cooler at 4 mtrlevel plateform. my question is, at 11 mtr height level the quantity of water and flow is not sufficient for my cooler, the temp. of cooler is rises much more. you are requested to suggest the modification of pipe line/ pump for take more water flow and pressure (desired pressure is 1 kg/cm2)

2402


what are the difference between AC lamp and DC lamp