Engineering AllOther (1379) How to justify this statement ??? "Capacitors in series provide less capacitance but higher voltage breakdown rating for the combination"
1893A 100W electric lamp is supplied from a 115V, 60HZ source. The peak instantaneous power dissipated in the lamp filament is
2395i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.
2135we use Dyn11 trafo for distribution purpose, if it`s possible for replacing Dyn1. if it`s change means what will happen?
1 5086what is the max. and mim. height of vertical post in informatry sign board which is used in highway projects.
2766what is the difference between delta delta and star delta connection transformer? why we use delta delta transformer since it need earthing transformer for grounding?
2103two transformers of the same type, using the same grade of iron and conducting material, are designed to work at same flux and current densities, but the linear dimension of one are two times of the other in all respects. The ration of kVA of the two transformer closely equal to................? options: 16, 8, 4, 2
2 15985
What is difference between conjugate beam and continuous beam ?
Explain why vestigial side band is used in tv signal transmission?
Explain the procedure in staring a F.O. purifier
If density of cement is 1500 Kg/m3, the how is specific gravity 3.15 ? (Density of water is 1000 Kg/m3)
A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.
State the types of distortions in amplifier?
the volume of cement req for 70cum of brickwork in 1:6 cement mortar is approx is equal to 3cum 5cum 7cum 1ocum
pls tell estimate for 1 kilometre length random rubble masonry 0.90 metre height 0.600 metre width
Bearing capacity of soil determined as per ASTM is to design the foundation size.what is the importance of EV1/EV2 value as per DIN .My consultant ask me to test the the soil as per din to find out this ratio to assess the compacted strength of soil ,,?? is it meaning full ??
EXPLAIN THE TERMS "INTEREST AND DEPRECIATION" AS APPLIED TO ECONOMICS OF POWER GENERATION.
what kind of quetions will ask in BHEL in interview? Plz help me?
Draw the circuit of cb configurations using npn transistor.
How to calculate ventonite bag in pile ( pile depth 25 m dia 1m)
Define hue?
Define encoder definition?