Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

if I did short to both AO connections, channel will burn or what? m sure in AI it will damage to channel. But what will happens in AO?

1 5181

What is Electrical Runout & Mechanical Runout in Vibration measurement.

1 8816

How can i test procedure grounding for CAT-7 cable? Or How can we test procedure CAT-7 Cable Electrically safe?

Tecnimont,

3021

why we are using negative range like -750 to 0 mmwc in closed tank?and what is the reason can you explain clear?

Aarvi Encon,

2 10516

when the force applied on load cell the ohms will be varriying .and how its convert ohms to mv generate and have any formulae?

UETCL Uganda Electricity Transmission Company Limited,

1 5762

can anyone tel the syllabus or previous year question paper for BHAVINI(EIE)2014.

Bhavini,

2492

If I installed wrong directions orifice plate then what showing value d.p transmitter?

Forbes, STS,

2 7619

Why integral control mode call Reset controller?

1 5486

TCD Principle

1 4972

What is the difference in clamp on type and inline type ultrasonic flow transmitter.

1 4160

I have a close vessel tank which is under vaccum when in running condition so pl. Provide it's range for dp type tx whose flange to flange distance is 440 mm and density is 1

1 3850

What is the definition of direct acting valve & reverse acting valve

2 6322

Rtd sensor how to calibrate

Sepam Group,

5 10950

HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME... SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,, I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION .. ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY MANIFOLD..!!! BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 , SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT.. THANKS YOURSSSSSSS

Torrent Pharma,

1 4539

HOW TO DO PERFECT CALIBRATION OF DIFFERENTIAL PRESSURE TRANSMITTER FOR CLOSE VESSEL TANK LEVEL PURPOSE ???? AND HOW TO MAKE ZERO PRESSURE ?? Rosemount 2051 Pressure Transmitter with HART® Revision 5 and 7 Selectable Protocol BIENG USED !! HOW TO CALIBRATE FIELD SIDE DPT WITH THE HELP OF SPAN & ZERO PUSH BUTTONS ??

Bhel,

1 7127


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

who's take first position in process in the timing of new installation flow transmitter and control vavle. give the answer with logical trick.

5303


Name different types of bourdon tubes.

1201


what does the ratio 800-400-300-200/1-1-1-1-1 in the specification of current transformer indicates?

2614


Can u tell me the principle of the tc,rtd,level switch,pressure switch ,transmitter(pr flow level temp.),vibration...plz

2108


A DP transmitter is used to measure the level of an open tank. The drain line of the tank is connected to a control valve, and is configured as, if the level of the tank is 90% the valve should get open 10%. And if the tank level is 10%, the valve should get open 90%. Draw wiring diagram and explain how to configure DP transmitter and control valve using HART communicator. If the span error at output is 1%, what will be the %opening of the control valve at 60% level of the tank?

1466


what would be the minimum flow rate that we can measure on rotameter..?

2152


IS there any effect of vortex in low pressure side of the transmiter after the orific in feed water line? if yes then what is the calculation?

2464


What is zone,loop/fire alarm system?

2757


If fire would be inside the plant which fire detector is to detected the fire.

1669


can we copy the software from a transmitter using hht(hart 275) ?

2143


What is the differerence between hysterisis and linearity.

2378


Why plc require in analog input 4-20amp & 0-10 volt?

1201


1. For Steam drum level signal, why do we compensate with drum pressure signal? 2.For main steam Flow signal is comensated with main steam temperature signal and main steam pressure signal why?

2279


what is the procedure of belt scale calibration?

2493


1- Explain about HPM 2- What is the FSC and explain the configuration of FSC 3- explain the complete loop of vibration, how it works (field to control room) 4- What is the use of proxymitter? 5- During job your partner effected with H2S then what you have to do. 6- what type of gland packing uses when valve glind is leaking.

2861