Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Instrumentation Interview Questions
Questions Answers Views Company eMail

if I did short to both AO connections, channel will burn or what? m sure in AI it will damage to channel. But what will happens in AO?

1 5096

What is Electrical Runout & Mechanical Runout in Vibration measurement.

1 8640

How can i test procedure grounding for CAT-7 cable? Or How can we test procedure CAT-7 Cable Electrically safe?

Tecnimont,

2952

why we are using negative range like -750 to 0 mmwc in closed tank?and what is the reason can you explain clear?

Aarvi Encon,

2 10378

when the force applied on load cell the ohms will be varriying .and how its convert ohms to mv generate and have any formulae?

UETCL Uganda Electricity Transmission Company Limited,

1 5670

can anyone tel the syllabus or previous year question paper for BHAVINI(EIE)2014.

Bhavini,

2444

If I installed wrong directions orifice plate then what showing value d.p transmitter?

Forbes, STS,

2 7494

Why integral control mode call Reset controller?

1 5390

TCD Principle

1 4879

What is the difference in clamp on type and inline type ultrasonic flow transmitter.

1 4070

I have a close vessel tank which is under vaccum when in running condition so pl. Provide it's range for dp type tx whose flange to flange distance is 440 mm and density is 1

1 3745

What is the definition of direct acting valve & reverse acting valve

2 6201

Rtd sensor how to calibrate

Sepam Group,

5 10711

HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME... SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,, I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION .. ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY MANIFOLD..!!! BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 , SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT.. THANKS YOURSSSSSSS

Torrent Pharma,

1 4443

HOW TO DO PERFECT CALIBRATION OF DIFFERENTIAL PRESSURE TRANSMITTER FOR CLOSE VESSEL TANK LEVEL PURPOSE ???? AND HOW TO MAKE ZERO PRESSURE ?? Rosemount 2051 Pressure Transmitter with HART® Revision 5 and 7 Selectable Protocol BIENG USED !! HOW TO CALIBRATE FIELD SIDE DPT WITH THE HELP OF SPAN & ZERO PUSH BUTTONS ??

Bhel,

1 7025


Post New Instrumentation Questions

Un-Answered Questions { Instrumentation }

Whether the DI, DOs shields can be connected with Analog Input Shield Earthpit?

1990


How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer

2779


How to calibrate level transmitter with use of HART?

2758


How many are the types of instrument cables in terms of No. of pair.

2191


I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.

1791


Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.

2078


what is the PC interface and software for connection to ABB logic module “ LM011-CE18RAC “ ( for Programming ) ??

4012


i am from instrument branch i want paper patern of mahagenco . any pevious years paper regarding my branch send me please . please.....

2090


If a warning lamp will operate with the ground circuit is bypassed with a jumper wire to ground, what should you check?

2080


Who to difference between analog in & analog out in dcs?

1660


TECHNICAL/ARTITUDE

2249


How to convert mmWc(mili meter water colam) to tph(ton per hour)?

981


Emergency Shutdown Systems/ Plant Shutdown System.

2267


What is standard procedure of manual mapping in Radar type level transmitter?

1946


What is difference between ESD and PLC please Explain me clearly.

4891