Torrent Pharma Interview Questions
Questions Answers Views Company eMail

how calculate column dead volume in hplc ?

3 21399

why 0.005 M sulphuric acid is used to calbrate spectrophotometer and why caffiene is used for calibrating hplc

2 20943

When we calculate Impurity against impurity std.solution and when we calculate impurity against diluted standard with applying RRF?

2 10701

in dissolution why pool sample needed? in which type of drug pool sample need?

2601

what is basc principle of the HPLC,IR,UV AND GC? what is difference between diffusion spectra and transmision spectra in IR?

1 20399

plz tall me that any pharmacopeia and guideline is par meted to use 1.68,4.01,7.00,9.00,12.45 buffer for ph meter calibration

2 3853

what is the difference payment terms in company codelevel and purchase organisation level

1 11921

how much wave length of Soduim vapour lamp used in polarimeter

2 9674

Relation in between KWH & KVAH for Electrical consumption unit & how we can relate if KWH is lower than KVAH

11 139121

IN DISSOLUTION WE ARE USING A LETTER 'Q' WHAT IS MENT BY Q

5 12764

Why we use basket in place of bowl in dissolution apparatus

3 8493

Why 1800 ml of dissolution media used In Carbamazepine ER USP Tablets But other drug only 900 ml Media Used ?

1 4720

Diff between Earthed & Unearthed cable ?

1 4294

what is the balance drift?

2 10605

HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME... SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,, I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION .. ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY MANIFOLD..!!! BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 , SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT.. THANKS YOURSSSSSSS

1 3774

Post New Torrent Pharma Interview Questions




Un-Answered Questions

Is empty function in python?

477


What are pull and push mvc architecture and which architecture does struts2 follow?

509


How set mysql root password?

494


Name different types of NoSQL database?

70


What is a call-up point? : co- cost center accounting

640






Can we configure two instances of CMS pointing to two different CMS system databases?

1499


How to gain more profit with even less sales?

665


What is python distutils?

444


How many test cases u will write for Acceptance testing?

1796


Can you explain the 'between' clause?

544


How does a sound wave travel in air?

557


Are spark dataframes distributed?

212


When is a dedit note raised When is an expense booked

1692


What is filter chain?

539


Illustrate the sandals of ancient Egyptian people.

5