Torrent Pharma Interview Questions
Questions Answers Views Company eMail

how calculate column dead volume in hplc ?

3 21881

why 0.005 M sulphuric acid is used to calbrate spectrophotometer and why caffiene is used for calibrating hplc

2 21425

When we calculate Impurity against impurity std.solution and when we calculate impurity against diluted standard with applying RRF?

2 11007

in dissolution why pool sample needed? in which type of drug pool sample need?

2750

what is basc principle of the HPLC,IR,UV AND GC? what is difference between diffusion spectra and transmision spectra in IR?

1 20658

plz tall me that any pharmacopeia and guideline is par meted to use 1.68,4.01,7.00,9.00,12.45 buffer for ph meter calibration

2 4175

what is the difference payment terms in company codelevel and purchase organisation level

1 12284

how much wave length of Soduim vapour lamp used in polarimeter

2 10016

Relation in between KWH & KVAH for Electrical consumption unit & how we can relate if KWH is lower than KVAH

11 140582

IN DISSOLUTION WE ARE USING A LETTER 'Q' WHAT IS MENT BY Q

5 13257

Why we use basket in place of bowl in dissolution apparatus

3 8844

Why 1800 ml of dissolution media used In Carbamazepine ER USP Tablets But other drug only 900 ml Media Used ?

1 4957

Diff between Earthed & Unearthed cable ?

1 4460

what is the balance drift?

2 10879

HELLO FRENDS ,, I M IN THE MIDST OF TROUBLE .. JUST LITTLE HELP ME... SUPPOSE ,, I HAVE A CLOSE VESSELE TANK ( HEXANE MEDIA ) ,, I M USING ROSEMOUNT 2051 DPT FOR LEVEL APPLICATION .. ITS CALIBRATE RANGE IS.. . 0 TO 950 MMH20 ..I DID CALIBRATED DPT WITHOUT REMOVING IMPULSE LINE OF HIGH AND LOW TAPPING.. & WITHOUT DISTURB 3 WAY MANIFOLD..!!! BUT ,,, DURING CALIBRATION I SELECT RANGE BY HART LRV IS 900 MMH20 & URV IS 1300 MMH20 ,, BUT ,TANK LEVEL SOMETIMES 100 % AT 1100 MMH20 , SOMETIMES 1300 MMH20 ..IN THIS CONDITION .. WHOLE LOOP FAILED ,, MAIN THING IS THAT ,, HOW TO CUSTOME RANGE SELECT ?? AND IF I USED RANGE OVER THE ORIGINAL CALIBRATE RANGE ,,,THEN WHAT ERROR WILL BE COME ??? HOW TO ZERO CALIBRATION OF DPT... HOW TO ZERO TRIM BY MANIFOLD ?? AND FOR TANK LEVEL PURPOSE ... WHICH UNIT I CAN USE ??? IS THERE ANY CALCULATION OR CALIBRATION .. IF YEH .. THEN PLZ JUST GIVE ME CALIBRATION STEPS FOR DPT.. THANKS YOURSSSSSSS

1 3932

Post New Torrent Pharma Interview Questions




Un-Answered Questions

How can you keep track of different versions of code?

586


What are the types of caches in lookup?

701


Is mongodb better than other sql databases? If yes then how?

1


Write a program use a text field and display it using the actionscript?

525


Is bucket sort stable?

624






How do I create a multilanguage, single-file assembly?

623


can anybody tell me that from whr i download rational rose setup (free)?

1901


What is hybrid cloud?

436


What is c# entity framework?

597


How can you configure safe stop?

320


What are the limitations of the context filter?

275


What are the three types of views in powerpoint?

905


I need to learn everything I can about the different types of Test Activities (i.e., Test Strategy, Test Plan, Test Cases, etc.). What is the best online resource?

793


What would happen if the both source and destination have the same name?

521


What kind of preventive maintenance are there for transformer?

1925