Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why chromic acid wash is not recommended by USP for glassware cleaning?



Why chromic acid wash is not recommended by USP for glassware cleaning?..

Answer / b.gangatharan

According to USP chapter<1051>chromic acid is not recommended for glassware cleaning due to hazardous &toxic nature of the material.
Thanks,
Gangatharan.b
Caplin point,
Puducherry.

Is This Answer Correct ?    2 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

Why using 0.5% acetone in methanol mobile phase for HPLC Gradient performance check.

2 Answers   DRL,


What are the factors effect peak shape in HPLC ?

2 Answers   College School Exams Tests,


how to prepare low ppm solution from high ppm solution ?

1 Answers  


Why Deuterium lamp is used as UV light Source for UV.

4 Answers  


how std. of znso4

1 Answers  


why do we use around only 60 mg of K2cr2o7 in the UV calibration -control of absorbance test?

3 Answers   Reddy Labs,


which are the diffrent batches in the pharmaceuticals?

0 Answers  


why we want incorporate area of each solution of Intermediate precision and repeatability as well as Accuracy ? What is the use to incorporate area of each solution of Intermediate precision and repeatability as well as Accuracy ?

1 Answers  


in which situation require to take incident in validation?

0 Answers  


In HPLC Chromatographic separation Resolution equation is Rs = 1.18 (tR2 –tR1)/wh1+Wh2, Where, tR2 and tR1 is run time of eluent ratios of the distances from the point of application to the centers of the spots and the distance travelled by the solvent front from the point of application (retardation factor), and Wh1and Wh2 , is peak width of at half height. What is 1.18 ?

1 Answers  


why required specificity in valdation

3 Answers  


IN DISSOLUTION S1 STAGE 1 BOWL GOT 52%(Q POINT IS 80%)WHAT WE HAVE DO

9 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)