Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why 0.1M OR 1M Perchloric acid standardisation done after 24 hours?



why 0.1M OR 1M Perchloric acid standardisation done after 24 hours?..

Answer / b.gangatharan

For non aqueous titrations,the solution should be virtually
anhydrous.Acetic anhydride present in 0.1M HCLO4 solution will absorb all the water from HCLO4 and Glacial acetic acid within 24 hours and renders the solution virtually anhydrous.

Thanks,
B.GANGATHARAN,
CAPLIN POINT.

Is This Answer Correct ?    11 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

why reference flow required during hplc analysis on rid?

1 Answers  


U have 4 strengths have different coating meterial which one u chose to do forced degradation stady in validation

1 Answers   Reddy Labs,


i want model written test paper for the post of analyst in IOCL(indian oil corporation ltd) any one pls help me

0 Answers  


What is the procedure for UV-spectrophotometer calibration?

6 Answers  


Why potassium dichromate was using in Uv calibration?

1 Answers  


In case of HPLC coloums what is the difference Between C8 & C18 coloums & how can we select difference type of coloums like Inertial ODS , Hypersil BDS , ODS etc.?

4 Answers   MSN Pharma,


in api coa contains only process impurities and in product coa contains degradation impurities?

0 Answers  


What is difference between chemical Assay and Hplc assay?

2 Answers   Lee Pharma,


what is diffrence between specificity and selecivity?

0 Answers  


why you are using benzoic acid for water content determination in TEA

2 Answers  


why the same column give different retention time in hplc?

7 Answers  


What are the factors effect peak shape in HPLC ?

2 Answers   College School Exams Tests,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)