what will be the pressure in tank which has the total level of 2 meters and is filled 1.2 meters ?

Answers were Sorted based on User's Feedback



what will be the pressure in tank which has the total level of 2 meters and is filled 1.2 meters ?..

Answer / raghava prasad

If the tank is open & filled with water upto 1.2 mtr level
Pressure is 0.12 KG/cm2

Is This Answer Correct ?    9 Yes 0 No

what will be the pressure in tank which has the total level of 2 meters and is filled 1.2 meters ?..

Answer / abhisek mohapatra

1.2 kg pressure

Is This Answer Correct ?    5 Yes 3 No

what will be the pressure in tank which has the total level of 2 meters and is filled 1.2 meters ?..

Answer / vijayvaidya

1kg/cm2=10000mmwc=10mtrs
so,1.2 mtrs=0.12kg/cm2

Is This Answer Correct ?    2 Yes 0 No

what will be the pressure in tank which has the total level of 2 meters and is filled 1.2 meters ?..

Answer / rohiths990

Dear friends how can calculate ,i mean any formula using eg:tank total level is 10 meter. filled fluid is 7 meter what is the pressure anyone please explain me clearly

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Instrumentation Interview Questions

we are having yokogawa centum cs3000 dcs in our power plant. i need some of the operator guides NOT to appear in HIS0163 AND HIS 0162 but it shoul appear in HIS0164 HOW TO DO IT?

0 Answers   Yokogawa,


what is the diffrence between pressure safety valve & pressure relief valve....pls

0 Answers   Oil India,


where i can get training in INTOOLS and PDMS in Delhi-NCR OR north part of India. please reply with ur ans. at arunsamkaria@ymail.com

0 Answers  


What is the different between ESD & PLC.

1 Answers  


To find closed tank level by DP transmitter , how to findout its range.and insomeplace they using range like - 1500 to +1500 mmwc why not 0 to 3000 mmwc. how they spilit they range for minus and plus.and why?

1 Answers   Kuwait Oil Company,






Can anybody tell me application of PLC,DCS,SCADA.

3 Answers   Reliance,


how the arrangement of equipments done in control room

0 Answers  


how can we tune a PID. If it is by zeiger nichols method..please explain briefly with help of an example.

0 Answers   KNPC,


How can we loop powered for a transmitter.How we can do wiring

1 Answers  


OBJECTIVE TYPE QUESTIONS OF ANALYTICAL INSTRUMENTATION

0 Answers   Fauji Fertilizer, GSECL, NFL, Power Plant,


Any one can help me to identified, how can we interchange the device in FF

0 Answers   Ion Exchange,


how works encoder in plc

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4451)
  • Electrical Engineering Interview Questions Electrical Engineering (16632)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)