Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why in GC calibration of linearity regression coefficient should not be less than 0.999



why in GC calibration of linearity regression coefficient should not be less than 0.999..

Answer / sunil shelke

Because the relationship between response and concentration is always 1.

Is This Answer Correct ?    8 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

what is the difference between lod and loq?

4 Answers   Apotex, Aurobindo,


differance between L1 and L7 columns

5 Answers   Everest,


why sre you used Potassium hydrogen phthalate in standarisation of 1N NaOH and 0.1 N Perchloric Acid?

1 Answers   Cipla, Elder, Vamsi Labs,


4. Describe the operation of the Craig apparatus. Chapter.3 Equilibrium Processes in Separations

0 Answers  


What is split ratio in Gc? Splitless? how requirr to select?

0 Answers  


If we have a kc is1*10^8 and the .kp 2*10^5 of reaction A------->B C------->D what is the volume of C?

0 Answers  


why we use pyridine to determine moisture content of acetonel

2 Answers   Lee Pharma,


why sucrose is used for polarimeter calibration

4 Answers   Sun Pharma,


which chromatographic technique is used for softening hard water?

1 Answers   Laurus,


signifcance of detector lenearity in calibration f hplc

3 Answers  


what are the different methods of analysing related substances test,what are LOD AND LOQ .HOW TO REPORT IMPURITIES WHEN LOD AND LOQ LIMITS R SPECIFIED

3 Answers   Dr Reddys,


For standardization of volumetric solutions, acceptance limit for concentration is considered as 10% of nominal concentration and %RSD as NMT 0.2% (for appropriate no. of replicates). But , if %RSD has not met, what should be further action?

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)