Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is the meaning of 624 in DB-624 Capillary column used in GC?

Answers were Sorted based on User's Feedback



What is the meaning of 624 in DB-624 Capillary column used in GC?..

Answer / viswanathan

DB-624 DB means Dura bond make
624 means usp code it containe:94%dimethyl polysilioxane and 6% cyno propyl phenyl

Is This Answer Correct ?    44 Yes 2 No

What is the meaning of 624 in DB-624 Capillary column used in GC?..

Answer / viswanathan

DB-624:DB means Dura bond make
624 means USP code for column packaging material.it contain

94% dimethyl poly siloxane,6%cynopropyl phenyl

Is This Answer Correct ?    25 Yes 1 No

What is the meaning of 624 in DB-624 Capillary column used in GC?..

Answer / rajendraprasad

Db means dura bond
624 means usp code
94% dimethyl poly siloxane,6%cynopropyl phenyl

Is This Answer Correct ?    11 Yes 1 No

What is the meaning of 624 in DB-624 Capillary column used in GC?..

Answer / sk.jilani

DB 624 it contains Dura bond which name of the brand
624 is USP code of list
this column is used for mid polar solvents to be determined

Is This Answer Correct ?    1 Yes 0 No

What is the meaning of 624 in DB-624 Capillary column used in GC?..

Answer / dhananjay

It is the brand name of column.

Is This Answer Correct ?    0 Yes 13 No

Post New Answer

More Analytical Chemistry Interview Questions

state the principle of gas chromatography?

5 Answers  


what are peak purity,peak purity index,peak thresold

2 Answers  


why we get negative values in uv when i placed sample which has some concetration but not in standard

1 Answers   Nirma,


What is calibration procedure of gredient HPLC pump

4 Answers  


In Karl Fischer titration,What is the situation if the material tested is only soluble in water,and not soluble in the common solvents used such as methanol ?? [e.g. Iron III Hydroxide polymaltose]

1 Answers  


What is the difference between STANDARDIZATION and CALIBRATION of instrument like KF? why do we standardization of KF everyday? Why the KF factor being only 5.02 etc? 

5 Answers   AlpaMed, Vergo pharma research,


wen v have polr solvent then which type of column use in hplc

2 Answers  


why equlirium conatant of water have 14 value

1 Answers   GVK Biosciences,


The boiling point of 1,3 butadiene is -4.4 DC & the boiling point of Pentane is 36.1 DC. Then how come Pentane elute before 1,3 BD in GC analysis?

1 Answers  


what is the purpose of Buffer in any titration?Ex:In determination of hardness of water we use ammonia ammoniachloride buffer in titration with EDTA.Why?

13 Answers   Amity, Prakriti, Sr Comunications,


what is motor rotation in case of sucrose

1 Answers  


why using buffers in hplc inteed of water

5 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)