Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the meaning of 624 in DB-624 Capillary column used in GC?

Answer Posted / viswanathan

DB-624 DB means Dura bond make
624 means usp code it containe:94%dimethyl polysilioxane and 6% cyno propyl phenyl

Is This Answer Correct ?    44 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have compare C2H2-air and C2H2-N2O flame AAS on determination calcium. Both use same range of std to plot calibration curve. (2-6ppm) When i measure the sample with phosphate, KCl and LaCl, C2H2-N2O flame give false positive result, around 0.5ppm. When i measure the sample with phosphste, KCl and EDTA. C2H2-N2O flame also give 0.5ppm false positive. But both above mentioned sample would not give false positive when measured by C2H2-air flame. What is the reason?

3540


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

2605


why we should take dst factor for below 1%moisture samples

2667


what is the importance of peak purity in HPLC and how we can calculate through manul(not software)?

4494


We use Potassium Dichromate solution for the calibration of UV-Visible Spectrophotometer in UV region. My question is to calibrate visible region which solution could be used in photometric accuracy

1909


Loss of linearity in tkn analysis, possible reasons?

1322


which batch require to use for analytical method validation?

811


Why irmoisture balance is used for corrugated box moisture testing

2404


What is the difference between Discriminating media and DPDM(Dissolution Profile with Different Media)

7549


how you start RS method development when for new product?

725


What is control room temperature and which guide line says?

1640


Why only 1.2 million lux hours require in photostability study?

1039


in which situation ion pair agent require to use?

741


4. Describe the operation of the Craig apparatus. Chapter.3 Equilibrium Processes in Separations

2722


IS THERE ANY EQUIPMENT TO CHECK AND CALCULATE THE POLARITY OF A LIQUID?

2465