How to calculate material requirement for 230mm thick, 1 sq.m
brick masonry?
Answers were Sorted based on User's Feedback
Answer / selva kumar j
TOTAL VOLUME OF BW IN CM 1:6= 1*.23=0.046 M3
BRICK REQUIRED - 11 5NOS
CEMENT REQUIRED - 11 KGS
SAND REQUIRED - 0.046 M3
| Is This Answer Correct ? | 11 Yes | 5 No |
Answer / rohit dhingra
volume of mix = 1x0.23 = 0.23 cum
no. of bricks = 0.23x500 = 115 Nos
as for mortar ratio is 1:6 assumed.
cement require = 1.25x0.23=0.2875 bag or say 14 kg cement
sand require = 0.23x0.23=0.052 cum
| Is This Answer Correct ? | 4 Yes | 2 No |
what will be the lap length of column reinforcement in case of welded lap
Sometimes the side of concrete bridges is observed to turn black in color. What is the reason for this phenomenon?
I'm diploma civil engineer. My question is what better after diploma 1- BE/B.TECH 2.EXPERIENCE Pls.suggest.
sometimes, in a column, reinforcement is provided equally on 2 sides and sometimes on 4 sides.what will be the difference in the method of designing?
which size of box use of cement,sand,aggregate to use the m 20 concrete. i know the quantity of material cement 400 kg or 8 beg ,662 kg sand and 1200 kg aggregate. i can use only 1 beg cement so pls give me answer . thx in advance
what will affect low density aggregates on concrete wt?
RCC colums of 15"X9" each, roof height 10.5'ft, total pillars 12 nons. Span between pillar to pillar is 14/20/20 length wise and 17/14 width wise. Total Slab area 2400 sft and plinth area is 1900 sft. beams are 12"X12". kindly calculate load factor per sqft.
2 Answers ABS Construction, L&T,
whike making bbs we deduct 2d for every bend in bar but theoretically we cant subtract 2d for every bend and for every dia of bar , so plz tell me the exact deduction for bends for different dia of bars and for different angles ??
if the nitrates more than 45mg/l in water lead to disease then what is it called
can any body tell me that we stdy different grades of concrete $ their strength . as we knot the strength of conrete that this grade or ratio of concrete has this much strength ? even that we go for labortory test what is reason behind that?
Which IS Code/American Code applied for coupler test of steel
Adout concrete
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)