Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


for which type of applications gas chromatography is used?

Answers were Sorted based on User's Feedback



for which type of applications gas chromatography is used?..

Answer / kiran11450

Compounds having Volatile nature and thermo stable compounds commonly we analysing in as chromatographic analysis.

Is This Answer Correct ?    3 Yes 0 No

for which type of applications gas chromatography is used?..

Answer / neelam kumari

gas chromatography is used fro application of hydrocarbon.

Is This Answer Correct ?    3 Yes 1 No

Post New Answer

More Analytical Chemistry Interview Questions

what is the difference between lod and loq?

4 Answers   Apotex, Aurobindo,


What is the difference between bulk property detectors and Solute property detectors vivimed labs limited

3 Answers  


HOW RRF IS CALCULATED IN HPLC

2 Answers  


how require to interprit the method precision data of hptlc?

0 Answers  


What is NPOC method in TOC?

1 Answers   Zydus Cadila,


What is the acceptance criteria for moisture balance when calibrated with sodium sulfate

0 Answers  


Why do we need GC instead of HPLC? or Why do we need HPLC instead of GC?

4 Answers  


UV and PDA detector, which have less signal to noise ratio?

0 Answers  


Why we use caffeine for HPLC calibration in Detector wave ength accuracy test

60 Answers   Arvind, Aurobindo, Cipla, Reddy Labs, Shasun Chemicals,


what is difference between assay&purity&potency?

5 Answers  


[3/30, 13:29] Manoj P Venkatpurwar: How hplc column selection according to structure? How mobile phase buffer selection on molecule structure?

0 Answers  


Plz explain the formula in uv calibration =Absorbance of the sample ( x ) x 10 x 1000/Weight of potassium dichromate taken in mg

1 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)