which type of motor we are using in local train???

Answers were Sorted based on User's Feedback



which type of motor we are using in local train???..

Answer / subbu

DC series motor using in Train because it can start with load....

Is This Answer Correct ?    23 Yes 0 No

which type of motor we are using in local train???..

Answer / swum

DC series motor cause of high starting torque, robust and
reliable, constant horsepower operation, can draw high
current for short period and good efficiency

For further info refer Electric Drives by P.K. Sen

Is This Answer Correct ?    17 Yes 1 No

which type of motor we are using in local train???..

Answer / g a reddy, essar steels ltd, v

Dc series motor used in local train. Because local trains has to stop/start for small distances i mean will stop at all stations. So for this type of applications DC series and compound motors will serve the high starting torque at low speeds. For local trains high starting torque is more important to save time. If we use other motors train will pick up speed slowly, so time span will be more to pick up speed.

Is This Answer Correct ?    8 Yes 2 No

which type of motor we are using in local train???..

Answer / ranjeetsinghbe

DC shunt motor... becoz in this motor load is directly
prop. to speed....

Is This Answer Correct ?    5 Yes 12 No

Post New Answer

More Electrical Engineering Interview Questions

for what voltage will reactive power be largest in 380 kv line : a) 375kv b)380kv c)385kv

0 Answers  


WHY THE +VE POLARITY OF 48V DC POWER SUPPLY IS USUALLY GROUNDED?

1 Answers   Tulip,


How to distinguish between the armature wires with the field wires of a Dc motor ?

5 Answers  


Define corner frequency?

0 Answers  


i want design of D.C.MOTOR 1HP 960RPM AND 2HP 960RPM ITS URRGENT

0 Answers  






how does an encoder work???

0 Answers  


How can we calculate ac current from the given DC current when AC voltage is given?

0 Answers  


what is the control circuit for operating the clean room air shower

0 Answers   L&T,


I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.

0 Answers  


why we use CVT (capacitive voltage transformer)in switch yard?

5 Answers  


if we connect a ohmmeter across shorted capacitor .what will be the reading..will it be zero or infinity

2 Answers  


Why 9KV surge arrester having 7.65KV of MCOV?

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5085)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4452)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)