how to caculate cutting lenght in bar bending schedule for
180 degree bend
Answers were Sorted based on User's Feedback
Answer / nil ratan adhya
180 degree bend means bar straightline or parallal line so cutting length actul dimentional length
| Is This Answer Correct ? | 36 Yes | 9 No |
Answer / vishal
for 90degree is 2d for 180 degree how much is cutting length
please answer from vishal
| Is This Answer Correct ? | 14 Yes | 5 No |
Answer / vinod kumar, sriharikota
GENERALLY 90DEGREES BEND IS 2D, 180DEGREES MEANS IT IS STRAIGHT BAR THE CUTTING LENGTH IS TAKEN INTO ORIGINAL LENGTH OF BAR.
| Is This Answer Correct ? | 5 Yes | 3 No |
Answer / anvesh
the standard bending shape is U..
the minimum cuttin length for 90degres bend should be 4d. nd
it should not 3d
for better grip..
the total length reuired for hook is 12d measured starting
from the point the bar start to bend.
| Is This Answer Correct ? | 3 Yes | 2 No |
Answer / amol pawar
For 135 180 and 90 degree bend hook length is 12D ,9D, 8D
Where D is diameter of bar
| Is This Answer Correct ? | 0 Yes | 1 No |
Answer / narendra
for 90 degree 6*diameter of bar and for 180
degree 9*diameter of bar
| Is This Answer Correct ? | 2 Yes | 5 No |
What is a BBS?Find out the cutting length for a 300*300 column with 40 mm cover?
21 Answers L&T, SSC,
hii.plz send me hpcl placement papers for officers trainees for graduate engg plz my email id is ajm_knit@yahoo.com
what is rigid pavement
What is '43' in OPC43 cement? What is '35' in M35 grade of concrete? Is there any link between them ?
What is the main difference between crushing test and impact test in coarse aggregate?
wat happens to the foundation when only live & dead loads are considered( wind load is excluded) during the design of tall structures. options are: a)only settlement in the internal structure and not external structure b)only settlement in the external structure and not internal structure c)no differential settlement d)none of the above
4 Answers BBJ Construction, IOCL,
what is lap length?
In foundation design, while we do the base pressure check, we normally check if the attained pressure value is less than the GROSS BEARING CAPACITY of the soil which is the sum of net bearing capacity of soil and the overburden pressure. Actually, the overburden pressure acts against the net bearing capacity of the soil and I feel that we are actually increasing the bearing capacity value and doing the check. I feel that this is NOT right. Please clarify on this.
There are two buildings one taller and one shorter whose time period will be grater and similarly the frequency ?
why you have choosen civil engineering as a carrier ,what goals do u have and how you wil aschiene it?
What is Shoe Footing ?
2 Answers Bhandari Associates,
What is difference between code and standard and specification?
Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379)