Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why cracks are being developed in a structure? any specific
reason? is there any remedial solution?

Answers were Sorted based on User's Feedback



why cracks are being developed in a structure? any specific reason? is there any remedial solution..

Answer / manish

Due to

1. Improper Mixing of aggrigates
2. Inefficient Pouring
3. Improper ratio of cement, sand, aggregates
4. Lack of Curing
5. Shuttering alignment is not Proper.

Is This Answer Correct ?    4 Yes 0 No

why cracks are being developed in a structure? any specific reason? is there any remedial solution..

Answer / mrdraj100

there is not any specific reasons for cracks: there are
variety of cracks that can occur in any structure (shear
cracks, flexural cracks)etc.....for these different cracks
there is different mechanism involved..for remedial solution
the reason behind the crack has to be found....

Is This Answer Correct ?    1 Yes 0 No

why cracks are being developed in a structure? any specific reason? is there any remedial solution..

Answer / ademola

There are series of crack in the structure of a building, but mostly it come the from the foundation due to settlement or improper mixing ratio of concrete, or if concrete contain too much impurities.

Is This Answer Correct ?    0 Yes 0 No

why cracks are being developed in a structure? any specific reason? is there any remedial solution..

Answer / nagarajan.v

Improper mixing proportions and curing its a main reason for cracks because the voids are formed in this structures. So the crack is easily to formed

Is This Answer Correct ?    0 Yes 0 No

why cracks are being developed in a structure? any specific reason? is there any remedial solution..

Answer / sagar bothare

CONTINOUS WATER SHOULD BE GIVIN TO RCC STRUCTURE. DURATION
ATLIST 7 DAYS

Is This Answer Correct ?    0 Yes 1 No

why cracks are being developed in a structure? any specific reason? is there any remedial solution..

Answer / arvind rai

In Rcc structure ,mainly cracks devloped .This is due to not
proper cover maintained.
Cover block should be fixed in between reinforcement and bar.

Is This Answer Correct ?    0 Yes 2 No

Post New Answer

More Civil Engineering Interview Questions

What is critical path method (c.p.m)?

0 Answers  


Why is the use of granular sub-base in concrete carriageways not preferred, explain?

0 Answers  


how we can estimate the M50 concrete for foundation?

2 Answers   Emirates, L&T,


What is the Unit weight of coarse sand (F.M- 2.20) ?????

0 Answers   BNF Group, TATA,


What is rolling stock

0 Answers  


cement mortor 1:5 for 30 m2 12 mm tk plastering so how to calcualte its rate

0 Answers  


what is the percentage of tolerance in the steel bars

1 Answers   Sunset Real Estate,


how you calculate the data (all parameter) after transient response method i.e.pile intigrity test on pile.

1 Answers  


What is standard sand? What is coarse & fine sand? What is foundation? What is the seze of hooks in various Reinforced section? What is the formula of providing clear cover? What is the basic diff. between working stress & Limit state design? What is &cbc and fck? what are the primary & secondary test of water purification?

2 Answers   L&T, TATA,


What is portland cement

3 Answers   CCCL,


1) what is the seewage discharge per person per day taken for design purpose as per IS codes? 2) how to convert gauge to MM like if we measure 18G as our door frame then how much is it in MM ? 3) how much binding wire is required ti tie 100kg steel ? 4) while making rings in steel reinforcement , whether the corners of rings are deducted to take out cutting length ? 5) how much carbon content should be there in steel used for construction purpose? 6) what are fe415 & fe 500 and which bars are used in general civil works?

1 Answers  


how can change 12mmdia@150c/c bar spacing to 16mmdia

2 Answers   Apex,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)