Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


How can we determine Moisture content of HI?



How can we determine Moisture content of HI?..

Answer / upendra

HI is strong acid, in Karl Fischer the pH limit is about 5 to 8, so first we have adjust the pH of HI.
For that we use imidazole.
Then we can seen the moisture as normal sample.
Thanks. Upendra Gohil
Reliance , jamnagar

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

who is the father of HPLC?

6 Answers   Cipla, IPCA,


in gas chromatography what is the difference between gas flow rate and average linear velocity ?

0 Answers   USV,


Whatn is HPLC

1 Answers   HPLC, Jubilant, Orchid,


if identification threshold crosses the limits then what next step?

0 Answers  


Home heating oil or furnace oil what is made from? Can (base oil plus diesel/kerosen) = home heating oil?

0 Answers  


Why the same type of columns showing different RT for a single product?

6 Answers  


Why KBr is used in FTIR ?

6 Answers  


control of resolution in calibration of IR

3 Answers  


In the method validation proceedure,lod & loq calculation we use the formulae for LOD=3.3*SD/slope and for LOQ=10*SD/slope,why we use 3.3 & 10 in the formulae?

1 Answers  


Describe 5 components of SFC ?

1 Answers   College School Exams Tests,


what is mean by UOD?

2 Answers  


Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?

0 Answers  


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)