Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


1 why polyesterene film used for ftir calibration ?
2 why k2cr2o7 is used for control of abs in uv ?
3 why holmium oxide used for control of wavelength in uv

Answers were Sorted based on User's Feedback



1 why polyesterene film used for ftir calibration ? 2 why k2cr2o7 is used for control of abs in uv ?..

Answer / d.lodhiya

1.IR spectrum is standars and peak is stable.
2. Because its having 2 peak and 2 vallay . stable and
standard upto 3 hrs. its obays bees law.(ABS .25 to 1A)
3. Its covers boths range UV and VIS.

Is This Answer Correct ?    9 Yes 2 No

1 why polyesterene film used for ftir calibration ? 2 why k2cr2o7 is used for control of abs in uv ?..

Answer / appalaraju

1.polysterene shows many distinct bands throw ir
2.Between this range it show observane limit.
3. In UV sharp peaks are rare.By using this H2O2 we get
sharpe peaks in UV>

Is This Answer Correct ?    3 Yes 1 No

1 why polyesterene film used for ftir calibration ? 2 why k2cr2o7 is used for control of abs in uv ?..

Answer / swat

poly styrene film stable at temperature.polystyrene made of polymer it can show 1589&1583&2849&wave numbers

Is This Answer Correct ?    0 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

What is the optimum period of storage of indicators?

1 Answers   Orchid Chemicals and Pharmaceuticals,


what is the principal of malvern particle sizer & its used in pharma industry

3 Answers  


How to prepare ppm solution of Nacl form its salt?

5 Answers  


why glutent are detected in the rice cereal baby food product even manufacturer claimed that they are using rice and milk only?we have using ELISA to do the test,and rice supposed not containing any glutent,rite?We already repeat the test so many times and it still detected.just wondering where the glutent came from?

0 Answers  


How to calculate lamp energy in hplc?

1 Answers  


What is the formula for Tapdensity /

6 Answers   Dr Reddys, GR Intrachem,


Why we have to take 42gm of sodium hydroxide instead of 40gm for preparation of 1M Sodium hydroxide as per Pharmacopia? Whether it means the formula for calculating molarity was wrong? 

5 Answers   Claris Otsuka, Ranbaxy,


Which detector is used in uv-vis spectrophotometer?

1 Answers   Glenmark,


What is Formula of Potency calculation on Dried basis, As is basis& Anhydrous basis.

11 Answers   Laurus, Teva API,


Is it nessesary all multimedia dissolution require descriminatory?

0 Answers  


In gas chromatographic analysis sometimes we use headspace, why it is required instead of manually injection?

1 Answers  


Which column is more polar, C8 or C18?

6 Answers   Cipla, Glenmark, Laurus, Torrent Power,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)