Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


why ct is testing using dc.. y cant we use AC insted of dc
on POLARITY TEST.

Answers were Sorted based on User's Feedback



why ct is testing using dc.. y cant we use AC insted of dc on POLARITY TEST...

Answer / k.prakashchandra

AC does not have fixed polarities

Is This Answer Correct ?    4 Yes 0 No

why ct is testing using dc.. y cant we use AC insted of dc on POLARITY TEST...

Answer / k.prakashchandra

Dc is not applied continuously. It is just touch and go, to
create momentary flux.

Is This Answer Correct ?    4 Yes 0 No

why ct is testing using dc.. y cant we use AC insted of dc on POLARITY TEST...

Answer / raj

then how we are using dc on test ..dc wont step up or step
down.., hw dc is craeting current that was shown in galvano
meter . please explain briefly..?

Is This Answer Correct ?    4 Yes 1 No

why ct is testing using dc.. y cant we use AC insted of dc on POLARITY TEST...

Answer / er dhananjay kumar

Actually in dc genertae constant flux. When we puch on buttons the contant have to travel from one side of ct (p1) to another side of ct (p2) and in this traveling. The flux is cut by ct winding all this event exist for micro second and this will induce a little potential across secondary side and in unidirectional that's why meter sow a little deflection

Is This Answer Correct ?    0 Yes 0 No

why ct is testing using dc.. y cant we use AC insted of dc on POLARITY TEST...

Answer / raghavendran.r

I think for Polarity testing AC is being used in power transformers.Let me explain the circuit for the same .Keep the secondary side open.But short one of the terminals of the secondary side with the primary side, so that the primary current flows through the secondary.Now adjust the primary voltage using variac and note down the secondary voltage.If primary voltage is greater than secondary then the polarities are different.
If secondary voltage is more than primary then the polarities are same.
This is how polarity is tested in power transformers and Motors.
The same may apply to CT also.

Is This Answer Correct ?    0 Yes 1 No

why ct is testing using dc.. y cant we use AC insted of dc on POLARITY TEST...

Answer / gopi

IN AC LOSSES HIGH. BUT DC LOSSES IS LOW

Is This Answer Correct ?    2 Yes 4 No

Post New Answer

More Electrical Engineering Interview Questions

Define CT & its function

6 Answers   Essar,


can indirect loading be called as phantom loading?

0 Answers  


Why consider motor rpm to select capacitor for motor

1 Answers   KSEB,


pls tell what are doing the three phase motor star and delta connetion with circuit diagram and control wiring .

0 Answers   Mukand,


how 650 volts creates? where is use?

0 Answers   DCL,


can we make a loop between neutral and body for grounding?

2 Answers  


On 400 amp factory load how kvarh capacitors provide

0 Answers  


How much weight an electrical engine can pull??

0 Answers   Maruti Suzuki,


sometime battery charged and then automatically charged when rectifier ON conition, is there any chances please clarify the same.

1 Answers  


what is meant by differential protection of transformer

1 Answers  


When PRV operated at power transformer ,can anybody tell me particular pressure for 50mva transformer plzzz.

1 Answers   BWSSB,


i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)