why ct is testing using dc.. y cant we use AC insted of dc
on POLARITY TEST.
Answer Posted / raj
then how we are using dc on test ..dc wont step up or step
down.., hw dc is craeting current that was shown in galvano
meter . please explain briefly..?
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
When the relative speed between the magnetic fields of stator and rotor does is zero under steady state operation?
why the earth is taken minimum in supplying? wather it the proportional factor to getting work any equipment or a power plant?
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?
The principle of switching circuits for different types of batteries in application of storage systems
can i use ups power as a raw power for another ups
What are reasond for high wattage in single phase induction motors
which IS or IEC is used for earthing,breakdown voltage of transformer oil, hv/pd testing and all type of electrical testing
What is the lifetime of a Thyristor? Is there a recommended lifetime for thyristors after which they should be replaced?
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
How to calculate the value of earth capacitance in a transmission line.
Some times to change of DOR of a motor, interchange of R & B is not effected and RYB take same current, but interchange of R&Y is effected ie change the DOR. My doubt is what is the problem in motor and how it is happen.
What is a copper loss or i2r loss pc?
why dimmerstate always connected in star connection? what will happen if it connected in delta?
HOW TO CALCULATE EARTHING SIZING?
what will happen if frequency is below 50 hz?