Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


Why use in sodium salicylate in uv lamps calibration



Why use in sodium salicylate in uv lamps calibration..

Answer / sivasantoshkumar.v

To detect the compount by uv in its structure, that absorbs uv light,
and gives a clear spot. and that can tell us that wether
our cabinet is detectiong the spots properly by emissing
the selected wavelenghts or not.

Is This Answer Correct ?    1 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

What is difference between assay by Hplc and uv

2 Answers   Aizant, Fredun Pharmaceuticals, Hetero, Marksans Pharma,


How to now that my acid is contact with base or base is contact with acid in drugs, is there any techniq to identify the formation of salt(drug)

3 Answers   Reddy Labs,


why salicylic acid not use for dissolution.

2 Answers   Cipla, Indo Baijin Chemicals,


How to Calibrate NMR instrument ?

1 Answers   Reddy Labs,


why using the ph 4,7,9.2?

1 Answers   SRF,


What if impurity area in control sample coming more as compared to LOQ level of impurity ?

0 Answers  


how can we determine RRF value in HPLC FOR CALCULATION OF IMPURITY ?

4 Answers   Macleods,


In UV we measure absorbance , how it is happend ? explain me

4 Answers  


in each media we require to use SLS? how to proceed?

0 Answers  


analytical method validation require to with respect to release specification or shelf life specification?

0 Answers  


What is the diffrence between the performing of LOD ordinary drying at voven and vaccum method.

4 Answers   Apex,


why KBr is used in FTIR SPECTROSCOPY and why is it necessary to triturate KBr during FTIR analysis?

25 Answers   Hikal, Lupin, Wockhardt,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)