Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


What is reaction takes place when water content analysis is
done

Answers were Sorted based on User's Feedback



What is reaction takes place when water content analysis is done..

Answer / v

OH + SO2 = ALKYL SULPHATES
ALKYL SULPHATES + I2 = SALT
SALT+WATER = LIBRATE I2
IT WILL GIVE END POINT

Is This Answer Correct ?    15 Yes 0 No

What is reaction takes place when water content analysis is done..

Answer / suresh palacharla

CH3OH+SO2+BASE----Alkyle Sulphate Salt+water+I2+base-----salt


water and Iodne are consumed 1:1 ratio.Once all of the water
is consumed, the presence of excess iodine is detected as a
end point

Is This Answer Correct ?    6 Yes 0 No

Post New Answer

More Analytical Chemistry Interview Questions

In BP2013, Loperamid HCl monograph. Assay by titration with 0.1N sodium hydroxide using hydrocloric acid 0.01N and reading the volume added between the 2 points of inflexion. I have a question that if the diluent solvent is ethanol is certainly consumed a amount of volume of titrant, so this volume must be eliminated on the result calculation or not apart from first point which is subtracted above.

0 Answers  


What about karl fischer reaction mechanism ?

2 Answers   Aurobindo, Mylan,


How can we Qualify a unknown impurity by HPLC

3 Answers  


What is the diffrence in japan mkt requirement in analytical method validation over US?

0 Answers  


In the gas chromatography what is used carrier gas and make up gas?

1 Answers  


In lcms analysis some times we get sodium and potassium adducts. if the compound is havine sodium ions how can we confirm wether sodium is from sample or it is a adduct?

2 Answers   Teva Pharmaceuticals,


why we can use only 4 and 7 and 9 buffers in pH calibration

1 Answers   Chola, Cipla,


loss on drying we applied vaccum for some compounds and some compounds are at 105c why

3 Answers  


what is a placebo peak

2 Answers   GMP Pharma, Optimus,


what is the structure of DOWEX-50

0 Answers  


what is icdas abbrivation

1 Answers  


why we use prednisone tablet in chemical callibration of dissolution apparatus?

6 Answers   Cipla, Mylan, Umedica Laboratories,


Categories
  • Organic Chemistry Interview Questions Organic Chemistry (342)
  • Inorganic Chemistry Interview Questions Inorganic Chemistry (123)
  • Analytical Chemistry Interview Questions Analytical Chemistry (1387)
  • Physical Chemistry Interview Questions Physical Chemistry (62)
  • General Chemistry Interview Questions General Chemistry (478)
  • Chemistry AllOther Interview Questions Chemistry AllOther (190)