Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


what is the specification for silt content in sand

Answers were Sorted based on User's Feedback



what is the specification for silt content in sand..

Answer / jayavijayan k

SILT Content in Sand should not be more than 7% by Volume.
( means upto 7% can be used without Washing).

Silt content of a Sand is meaured by folllowing
Procedure,
a) Take a clean 200ml. measuring jar
b) Fill with sand upto a certain mark ( say reading 'X')
and add water above it upto 200ml. and shake well.
c) Allow a period of 2hours for settlement
d) Clean sand will settle at the bottom with silt and clay
impurities on top of the sand layer.
e) Now oserve the top level reading for sand. Assume that
is 'Y'. Then the silt contain in % is given by,
% Silt content = (X-Y/X)*100

Is This Answer Correct ?    161 Yes 50 No

what is the specification for silt content in sand..

Answer / naresh

(X-Y/Y) * 100

Is This Answer Correct ?    67 Yes 38 No

what is the specification for silt content in sand..

Answer / dharmendra

x is the initial mark , but after adding water and waiting
for 1 hr then we have to take the SAND+SILT = A ml , and
then the only sand level say B ml

silt content = (A-B)/B *100


AND (X-B)/B*100 is BULKING OF SAND

Is This Answer Correct ?    39 Yes 16 No

what is the specification for silt content in sand..

Answer / sathish

IS code 383 Reference

Maximum allowed for 3% in wet sieve analysis method

75 micron sieve ..used

example
wet sand samle oven heat by process
Then Dry sand 500 gms
IS sieved 75 micron
same value reduce 478
= 500-478 =22
=22/478*100
=4.60%

Is This Answer Correct ?    25 Yes 8 No

what is the specification for silt content in sand..

Answer / qc

I want to know one what is (SILT Content in Sand should not
be more than 7% by Volume.) reference is where?
ACI ASTM or BS?
What?

Is This Answer Correct ?    14 Yes 5 No

what is the specification for silt content in sand..

Answer / manjeet ahlawat

it should be (A-B)/B*100

Is This Answer Correct ?    5 Yes 1 No

what is the specification for silt content in sand..

Answer / shubhangi gosavi

It should be (y-x)/x * 100

Is This Answer Correct ?    22 Yes 19 No

what is the specification for silt content in sand..

Answer / idrees jae

yeah,i am of the opinion that answers 1 and 2 are correct depending on the perspective.
answer 1,gives you the actual % of silt while answer 2 gives you the worse case.

Is This Answer Correct ?    12 Yes 9 No

Post New Answer

More Civil Engineering Interview Questions

How can I check the quality of sand,brick,and aggregateat site without using any labouratory test?

1 Answers   CCCL,


What are the phases inspections are done by local authority while construction?

0 Answers  


what is smart building materials?

0 Answers  


How much kg or MTs of steel is required for construction of the building of 1000 sqmt.

4 Answers  


Please give me the mixing ratio for higher grades of concrete (M30, M35, M40, M45, M50) using cement, VSI sand (Maharashtra) and metal. In case any other additives are supposed to be added to my concrete please let me know about that as well.

1 Answers   Core Consultants,


Ratio for 4500 psi concrete

0 Answers  


how much steel is required foe following components.. footing- plinth beam- column- beam- slab-

1 Answers  


6mm dia rod legth 1feet

5 Answers  


What is eccentricity in laymans term Can't understand bookish language .please explain in easy way.

0 Answers  


Consumption of Binding wire for fixing of cover block in vertical surface

0 Answers  


List out some of the software program that can be useful for architect?

0 Answers  


how to calculate 110kv transmission line tower stub top and bottom diagonals

0 Answers   ACME,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4453)
  • Electrical Engineering Interview Questions Electrical Engineering (16638)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)