Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


what is relation between electronics&instrumentation

Answers were Sorted based on User's Feedback



what is relation between electronics&instrumentation..

Answer / anish kumaran

Electronics is t back bone of instrumentation to get better
contol actons .Eletronics playing a vital role in
instumentation.Eg. Take a transmitter to convert The
physical quantity in to elecrical it needs electronic
components...

Is This Answer Correct ?    18 Yes 0 No

what is relation between electronics&instrumentation..

Answer / vlad

E&I means Electrical and Instrumental

Is This Answer Correct ?    0 Yes 0 No

what is relation between electronics&instrumentation..

Answer / faiyaz ahmad

Electronics- is flow of electron that is called electronics.
Instrumentation- is branch of science deal with the difference parameter that is called Instrumentation.

Is This Answer Correct ?    0 Yes 0 No

what is relation between electronics&instrumentation..

Answer / bhanu pratap

Instrumentation is the application part of Electronics. In Electronics we study the basics of instruments and then apply it in Instrumentation.

Is This Answer Correct ?    0 Yes 1 No

Post New Answer

More Instrumentation Interview Questions

i m passed my engineering in 2010 in instrumentation and control engineering. my question is can i apply for software jobs or vacancies.??????????? plz give me answer soonnn......

2 Answers  


why we require Differential pressure?Why we use Orifice Plate?

3 Answers  


what is the difference between signal cable and ontrol cable?

14 Answers   Essar,


what is the function of 3 way manifold valve in a closed loop system?

1 Answers   Emerson,


Instrument QA/Qc what is the project quality plan?conduit inspection RFI. which documents attache with package?

0 Answers  


Someone Please tell me what are the Pre-Commissioning activities in a Thermal Power Plant for an instrumentaion Engg.

0 Answers  


we callculat main steam flow by D.P. but where is H.P. & L.P. IN Orfics?

3 Answers  


We have ZR22G-100-S-A-E-T-T--E-A/CV/F1 Model Zirconia Oxygen analyser which is Yokogawa make. I kept the analyser in Flue gas path at Air pre heater area. My plant is 7.5MW Biomass power plant. For a particular fuel, Coconut Husk which contains Sodium and Potassium chlorides iam not getting proper reading, Analyser output always Zero. I calibrated the analyser and it is OK. For Other fuels like Wood chips, Cholam waste, DOB, Groundnutshells, Ply wood waste and all iam getting actual percentage of Oxygen. What is the main reason behind this draw back?

2 Answers  


can we use a control valve without positioner

19 Answers  


which instrument is most commonly used to observe the external features of a grasshopper's abdomen?

1 Answers  


What is glanding

1 Answers  


Yokogawa CENTUMVP R6.09 unable to download to Engineering Station with ExaOPC R3.75 The issue is when I try to download the common project section to the Engineering Station (STN) from the HIS in System View, it is unable to connect. The error displayed is: WARNING: Could not connect to equalize destination. (7001) Retrying. Number of retries = 0/1 ERROR: LdXopsLoadMain: connect error 10060 ERROR: Processing terminated due to connection error. (7002) Equalization end with errors. STN0149 ---- ERROR = 2 WARNING = 1 ---- Background: >Updated the ExaOPC software on the STN from 3.60 to 3.75 >STN operating system is Windows Server 2008 R2 >HIS operating system is Windows Server 2016 Stanard Solutions attempted include: >Ensuring all IP addresses are correct and all networked devices can be pinged. >The ability to ping a device using its host name from another device (<ping STN0149> from HIS) >Ensure both devices firewalls are disabled. >The antivirus installed on the STN is disabled. >Ensuring both devices are within the same workgroup. >Added both devices to each other's Host and LMHost files. >Running IT Security tool after changing any administrative settings.

0 Answers  


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)