Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...


calculate the rane of level use of this values, h=3 meter
density=0.9 , whats the rang?

Answers were Sorted based on User's Feedback



calculate the rane of level use of this values, h=3 meter density=0.9 , whats the rang?..

Answer / ram

3000 mm * .9 = 2700 mmwc

Is This Answer Correct ?    17 Yes 0 No

calculate the rane of level use of this values, h=3 meter density=0.9 , whats the rang?..

Answer / bhanu

the density is wrong. It must be specific gravity 0.9.
range is specificgravity x hight in inches ( the answer is
in inches of water column)
the range varies from 0 to 300*0.9/2.54 " w.c

Is This Answer Correct ?    4 Yes 5 No

Post New Answer

More Instrumentation Interview Questions

What are the two program execution modes of PLC?

4 Answers  


why 8bit microprocessor referred as 2^16?

2 Answers  


What is mean by analytical instrumentation?

0 Answers  


Difference b/w SCADA & DCS

8 Answers   Siemens,


what is instrument termination

1 Answers  


dear sir we have insatlled positioner model no.sipart PS2 make Siemens at our control valves . now problem is if we want to increase the response of valve opening speedy /fast. what parameters do we change for positioner ? any idea. please guide us.

0 Answers   CPL,


how to design orifice plate?what is the equation?

0 Answers   REL,


what is a good line as ic engineer as maintenance ,oc, project, calibration ,validation engineer?

0 Answers  


why we are using ungrounded RTD sensor and what is difference between grounded RTD and Ungrounded?

1 Answers  


why level transmitter input is given 4to20ma

2 Answers   Sabic,


how u meassure a room temp?in rtd or themo couple?

4 Answers  


HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.

0 Answers   Reliance,


Categories
  • Civil Engineering Interview Questions Civil Engineering (5086)
  • Mechanical Engineering Interview Questions Mechanical Engineering (4456)
  • Electrical Engineering Interview Questions Electrical Engineering (16639)
  • Electronics Communications Interview Questions Electronics Communications (3918)
  • Chemical Engineering Interview Questions Chemical Engineering (1095)
  • Aeronautical Engineering Interview Questions Aeronautical Engineering (239)
  • Bio Engineering Interview Questions Bio Engineering (96)
  • Metallurgy Interview Questions Metallurgy (361)
  • Industrial Engineering Interview Questions Industrial Engineering (259)
  • Instrumentation Interview Questions Instrumentation (3014)
  • Automobile Engineering Interview Questions Automobile Engineering (332)
  • Mechatronics Engineering Interview Questions Mechatronics Engineering (97)
  • Marine Engineering Interview Questions Marine Engineering (124)
  • Power Plant Engineering Interview Questions Power Plant Engineering (172)
  • Textile Engineering Interview Questions Textile Engineering (575)
  • Production Engineering Interview Questions Production Engineering (25)
  • Satellite Systems Engineering Interview Questions Satellite Systems Engineering (106)
  • Engineering AllOther Interview Questions Engineering AllOther (1379)