Does dry and oil transformers both require dedicated neutral, because in my project we are using 2500kv dry star delta transformer, where they say neutral not required and even it is not provided in our substation. can u let me know
2 4150What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?
1783What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?
1676if a 2 ohm resistor,2 ohm capacitor and a 2 ohm inductor is connected parallely to 12v source.Then what is the value of current in each branch.Is current flows in each branch at the same time?If not so then provide the proper sequence
1 3122According to ohms law voltage proportional to current, then why should current rating is low with high voltage rating in transformer?
KEC,
5 7921Post New Electrical Engineering Questions
2- What are the percentages between excitation currents in phase (R, S and T) in ∆ and Ỵ connections in excitation Current test in transformers?
What is meant by rotor?
What do you mean by pull of electromagnet?
what is diff. between earthing grid,earthing mess, earting grid?
I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?
1) Explain why we don't link the two earthing system ht and mv on a pole mounted transformer sub-station.
What is ideal IR values for ground and neutral.
WHAT IS MEANT BY TV TERMINAL IN 500MVA TRANSFORMER?
we have earthmat at 110KV substation.we would like to take earth resistance.b some says that by connecting earth megger terminals (C1,P1) at middile point of earthmat (at riser) will cause voltage gradient at other earthmat nods and dont get exat earth resistance.when connecting at end nods will get exat value . is it correct .please explain
What is contract demand in solar system?
Difference between on line capacitor and Station type capacitor
What is time response of the control system?
How colour picturetube works & how many year it will works.
during installation time of transformer and alternator which points we have to observed?
What is installed in PAC that is control the humidity