Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

The power supplied to a 50mH inductor from a 120V, 60Hz source will be

4794

A 100W electric lamp is supplied from a 115V, 60HZ source. The peak instantaneous power dissipated in the lamp filament is

2382

i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.

2122

we use Dyn11 trafo for distribution purpose, if it`s possible for replacing Dyn1. if it`s change means what will happen?

1 5062

How to know th details about an electrical Drawing ? Please mention the easy method.

Siemens,

2448

can we use ACB for HT supply

Reliance,

2 5285

When oil level in the oltc of power transformer reduces , oil surge relay will act or not

4 8478

Why in KVA diesel engine? Why not KW

3 5415

what is the difference between delta delta and star delta connection transformer? why we use delta delta transformer since it need earthing transformer for grounding?

2091

two transformers of the same type, using the same grade of iron and conducting material, are designed to work at same flux and current densities, but the linear dimension of one are two times of the other in all respects. The ration of kVA of the two transformer closely equal to................? options: 16, 8, 4, 2

Vizag Steel,

2 15962

What is the selection process of breakers. Can any one please give a formulation on same?

Sterling Wilson,

2161

How can we deside Short Ckt level of electrical System,Breakers etc.please provide formula to find SC of HV side & LV side

1849

th how could we differentiate between armoured copper and armoured aluminium cable what is the basic application? why we prefer the armoured copper as compared to armoured aluminium.

HMC,

1969

what is a FACTS devices? what is mean by STATCOM????

IIT,

1 8990

Hydro P.P. run @ 600 rpm,8pole, Nucler P.P @ 1500rpm 4 pole , ThermlP.P @ 3000 rpm 2 pole.Why this diffrence??? when we can generate electricity @ 600 rpm then Why we had incresed speed in NPP & TPP???

3 5086


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

When is lag lead compensator is required?

1124


What are the commonly used schemes for the bus zone protection?

1064


which of the following elements is not present in stainless steel

2537


When lag/lead/lag-lead compensation is employed?

1191


what is meant by poly phase induction motor ? how its operating by single phase or three phase?

2159


What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.

2333


Dear sir, How to calculate 3.5 core pvc aluminium armoured cable meter wise carrying amps rating.Please give the solution with a good example.

1887


The efficiency of a 100kva transformer is 0.98 at full load as well as half load , for this transformer what is the Copper loss at full load ?

2336


I have motor 1500 HP and , 4160 V , 60 HZ , then i need the rating of transformer which can feed that motor ??

1950


Is there any abbrevation for STUB in Stub bus protection

1941


Why Water motor is not taking a load or pressure while everything is correct. (Note: Motor running properly)

1403


11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?

1667


PLEASE SEND ME NTPC RELATED INFORMATION LIKE WHICH TOPICS HAV MORE SCOPE,BOOKS TO READ,CUT OFF...PLEASE.mail at thiru.1203@gmail.com

2108


How generating electric power export to grid from the generating station ?

1882


I have a 380 KVA DG set. How can i find out 1. My Fuel Consumption per hr ? 2. Electricity produced in 1 Hr. ? 3. If load varies then how does it affect fuel consumption & electricity produced ? Please HELP !!! Really need an answer.

2623