why do we need to use 3c+3e cable, normally i select only 3c+e cable and i think it is enough. pls explain the usefull of 3e cable ( in this project the earthing system is well done)
24227. Why AC motors, AC bulbs etc... are donot operated by DC signals? and Why DC motors, DC bulbs etc... are donot operated by AC signals?
Bhel,
2 5487Why AC loads wont used in DC input supply? and Why DC loads wont used in AC input supply?
Bhel,
3 73461. The DC generaror,s induced output emf is connected with a DC motor(as load). when increasing the load of the motor by using brake drum or any way. what are the parameters will changes in both motor and generator(voltage, current, resistance, frequency, speed, torque, power, flux etc...) 2. Similarly for AC generator and AC motor 3. similarly if using DC batteries instead of DC generator, What happens?
22481. for eg, capacitor is used for many purposes(it act as filter, oscillator, bypass capacitor, memory storage etc...) 2. Please tell me some example circuits for different uses of capacitor( whenever and whereever and however we used capacitor as a filter, oscillator tuning etc..) 3. similarly for inductor and resistors(it act as what?) and when and how we want to act as like that?, and how we can used these components depends upon our requirments with example circuits and explanation? design to act as these components depends
1783Is it possible to convert Dependent sources to its equivelent current or voltage Sources ?????
1 2998Hello friends i am facing one problem in lighting panel. Frequently neutral link near to MCCB is burning(firing. What may be the reason for this one. Please answer me.
5 8056In short transmission line,why does the receiving end voltage is less than sending end voltage?
4 7317Post New Electrical Engineering Questions
What is current divider rule (cdr)?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
How to convert a two phase power into a three phase power in induction machine?
How to choose the vector group for the step up and step down transformers??? Tell me the which vector group is suitable for step up and step down transformers and whats the reason to choose and whats the benefits???
Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?
What range of speed can you get with the armature control method of speed control of d.c. Shunt motor?
how freewheeling diode improves the powerfactor
What do you mean by distribution transformers?
how to set relay setting? and example calculation...
Which Class insulation is prefered for the sandwich Busducts ? Why?
difference between power surge and switching transient
how to calculate the lightning arrester conductor @ no of earth pits required
How to address the servo drive for motor
what is the differences between microprocessor and general purpose computer
Is there any relevant technique to produce power from light and heat energy of the sun simultaneosly from same rays of light?