Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

how squirrel cage & slip ring motor works? how they differ from each other

1 5550

why the earth pin in a 3-pin socket is longer and thickest?

5 9440

which is better 50 HZ supply or 60 HZ supply?

6 12485

Difference between KW & kVA

7 11557

why -48 volts dc used in telecommucation

2753

What will happen if primary of transformer is fed with Square wave instead of sinsoidal wave ?Will it operate or Not?

Areva,

3 17435

i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester

2201

Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

Piramal Healthcare,

2181

Why indicate only 440V to 3-phase supply.

4 9419

whatis mean by voltage?

7 11056

Main Differance between Primary Distribution & Secondary Distribution Of Electricity....?

1 24852

Why is a synchronous motor always star connected??

Bhushan Power Steel,

2654

what is the benift of HT metering & LT metering

1 4876

what is the wattage of 'zero watt' bulb?

PSEB,

16 34859

Megger type of instrument is used to check??

8 10637


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

In case of HV test on medium voltage cables, BS is asking for 4 U0 where as IEC is asking for 3.5 U0. Can any one advise me how this 3.5 times or 4 times U0 is derived?

1748


why are installed water leakage detection system data centers & server rooms

2467


how calculated Transformer losses.

2091


how to setting voltage RTCC panel

1715


What is the function of electron gun used in crt?

1127


What is meant by vector group

2630


Why the symbol of register is "zig zag"

1641


How to do fabrication , busbar and wiring cost for : 1. LT Panels 2. C& R Panel

1969


Can we use 230VAC, 63A MCB for 120VAC, 63A supplied heaters load?

1546


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to confirm its base capacity?

2023


what is the difference between electrical and electronic choke?

2024


Draw a circuit diagram in which if button is open we can use socket and bulb as a series test circit and if button is close than simple we can use socket as any load purpose.

1929


What are the criteria shall be considers for sizing Fuse and MCB? If the rated current is 10Amps what should be the fuse size / MCB Size?

1706


In vapour absorption refrigeration machine fluids used are

1303


Give accurate definitions for these electric terms: Inductor Inductance Inductive Induction Reactance Reactive Esam Baraka ٢١ ساعة

1454