What will happen if primary of transformer is fed with Square wave instead of sinsoidal wave ?Will it operate or Not?
3 17270i want to know how to determine that a surge arrester work properly in 11kv system. and how to test a 12kv surge arrester
2164Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
2130Post New Electrical Engineering Questions
How will you justify IR value and Charging voltage of any motor,transformer and Cables.......???? . . . . . . . . Plz tell me any body Baljeet Singh, engineer_89@refiff.com
Why is back emf used for a DC motor? Highlight its significance.
Write the programming software name for LG, SIEMENS,Messung,AB
what will happen if synchronous machine rotor fed from single phase ac supply
what is the ckt diagram of a tubelight and is it the simplest ckt of electrical engineering and also the component?
explain all the classes with example
is the value of inductance depends upon the evalue of thitha in doubly excited machine?
Why can't we parallel Voltage transformer secondary circuits?
Why the power factor improvement is so important in industrial loads
we are having 15kw and 3kw motor both can run in same time , instead of using copper we are using ug aluminium cable , 35 sq.mm is suitable for its current carrying capacity..?
what is zinc diffusion?
what is the chemical name and formula of refrigarent R-134a.
Both generator parallel condition shared load equally but one genrator taking ampere more than the other what are all the causes to make like this
If I have 3 essential main switch board and 3 incoming electricity ,but only 1 genset running is that possible.
dg started in plc mode and load taken later one battery terminal connection will be disconnected by loose connection what will happen for dg and shall we connect battery terminals while dg in load time?