Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Electrical Engineering Interview Questions
Questions Answers Views Company eMail

why dc is used in control circuits for MV & LV switchgeras instead of ac

1956

why dc is used in control circuit for mv & hv switchgear instead of ac

1924

what is the meaning of 0.5ohm Resistance

Vardhman,

1861

Advantage of 11KV ring main system with open point

Alam Group of Companies,

1 2652

Why Utility Distribution System in India is mainly at 11 kV? Why not Utility go for 33 kV?

1745

how we explain parallel paths armature winding?

1958

why 15 kw motor winding resistance is low then 5 kw motor winding resistance?

Baosteel,

2834

The coils having selfinductancs 10mh and15mh,effective inductance 40mh when connected in series aiding. what will be the equivalent inductance if we connect them in series opposing?

BSNL,

1 2256

what is the Pickup/drop off ratio in BCPU relays

DNJ Energy LLC,

4647

What is the breaking capacity of transformer and how can we calculate the breaking capacity of tranformer

Siemens,

1948

The magnitude of sum of two sinusoidal av voltage is equal to 230 volt.the magnitude of each individual voltage is also equal to 230 volt.what must be the phase difference between voltages?

PGVCL Paschim Gujarat Vij Company Limited,

1623

Three phase power is measured with two wattmeeter for balance three phase load.the reading of one wattmeter is zero.we can conclude that the power factor of balance load is?

1 2258

Consider three heater bank connected in 3 phase star with neutral.Each heater bank connected in each phase.So each phase get 230 volts supply.my question is,during balance condition, current flow in neutral or Not

1640

How to calculate multiplying factor of dc energy meter

1665

I have a 380 KVA DG set. How can i find out 1. My Fuel Consumption per hr ? 2. Electricity produced in 1 Hr. ? 3. If load varies then how does it affect fuel consumption & electricity produced ? Please HELP !!! Really need an answer.

2622


Post New Electrical Engineering Questions

Un-Answered Questions { Electrical Engineering }

1. What is the exact formula for one weber? for example,(one ampere = one coulomb electron of electrons crossing a point of conductor at one second. i.e, 1A=1Q/1sec)

1896


How to check 11000/1.732 to 110/1.732 Potentila transformer (PT)?

2207


Define filter?

1122


How capacitor improves pf

1712


hi, in the event earth grounding is not available in a project, is there any other way to make the elcb work? fyi, i have an instant water heater (6.5kw) installed, however if there is grounding in the heating element inside the heater assembly, i will get grounded. thank you in advance to those who will answer my question.

1991


We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.

1657


All tape of electrical questions Answers tape of motor transformer e.o.t crane

2657


What is touch potential and step potential?

2155


what is the function of bearing in dc mchine" and where it is placed

2582


what is the use of the circle diagram

5609


How to Calculate KA Rating of Main LT Panel

1750


Circuit diagram of tube light without starter using electrical choke

4126


what is spadar bar .why I use in DC generator.

1927


Whether should be the oil level in OCTC transfomer? It should be upto winding immersed completely or should be upto tap changer s/w? How it will affect the performance of the transformer. Rating may be 33KVA

1834


wat is the first thing dat is needed, 2 lay a cable in some area??

1859