Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) Based on the Job Description above, please indicate in details why you are a good match for this position?
2266DGs fuel and lube oil filters are not equal to one another.Why it is so.For example one MTU enginee fuel filter is one and lube oil filter-02nos other DGs are more.Please explain
1 2835What is the permissible sound level for 1000kva DG set and how the sound level is calculated.
1 3567why rotor winding in induction motor is not earthed. normally we uses star winding in rotor .why?
3 8852Hi all I had applied for the RRB test in the ELECRICAL category. I would be pleased if any of you can sent me previous year question papers. Please forward the question papers to varshashahi@yahoo.com Thanks and regards Varsha
2196Please sent me some previous year question papers of BSNL-JTO telecom and RRB in ELectrical Engineering to varshashahi@yahoo.com
2077
What is the formuala to calculate the rating of motor protection circuit breaker
please give me all the Alarm .Trip ,Safety Relays & Conditions of UPS Systems mail me on ashokbabunhce@gmail.com
what is the max. and mim. height of vertical post in informatry sign board which is used in highway projects.
what is meaning of 230volts ac 50hzs ac supply is it rms or maximum to getting ac 230v what amount of max voltage they will send
What do you mean by turns ratio of instrument transformer?
tell me about roaster switch .& what is the function in transmission & distribution?
What are you going to inspect or check when you open the crankcase?
11 kg trivevter meter has rating of -/5amps. And pt ratio11000/110v and is connected with 11kv ct/pt unit of cr ratio 75/5amps. And pt ratio of 11000/110v while checking accuracy of meter with HT Accuchek meter what value of PT ratio and CT ratio to be filled in Accuchek meter
On what basis the the size of Lightning arrester for buildings are selected ?
HOW TO SET THE EARTH FAULT SETTINGS IN ACB????????????
Which type of plywood & sizes using in construction projects ?
Which motor is 3.3 or 11kV more reliable, in terms of efficeancy,maintenance, reliability.
why we use cascade control and feed foreword control in 3 element control of boiler drum ?what is feed forward and cascade control system ?
How to calculate size of HT breaker with the help of Amp (current)? Please provide answers with examples.
What are the uses of memristor?