Civil Engineering (5086)
Mechanical Engineering (4456)
Electrical Engineering (16639)
Electronics Communications (3918)
Chemical Engineering (1095)
Aeronautical Engineering (239)
Bio Engineering (96)
Metallurgy (361)
Industrial Engineering (259)
Instrumentation (3014)
Automobile Engineering (332)
Mechatronics Engineering (97)
Marine Engineering (124)
Power Plant Engineering (172)
Textile Engineering (575)
Production Engineering (25)
Satellite Systems Engineering (106)
Engineering AllOther (1379) how can we understand that where we have to use ac or dc coil for solenoid valve and why?what is the different between coil of ac and dc explain please.
1980how can we determine size of a cable by knowing the kw or current rating of a load?how can we calculate the resistance box of a slip ring motor?
1764Does dry and oil transformers both require dedicated neutral, because in my project we are using 2500kv dry star delta transformer, where they say neutral not required and even it is not provided in our substation. can u let me know
2 4137what is meaning of inverted beam.is it way to provide double mat in slab one at bottom and another at topif we go for provision of inverted beam. shall we construct structure with out plinth beam for us we have to construct small bus shelter
2498What is the rating of circuit breaker needed for 300 KVA load in 33 KV supply line in a transformer of 33 KV / 415 Volt ?
1776What is the rating of a circuit breaker needed for 300 kv load in 33KV supply line of 33/415 transformer ? Whether 800/1200 amp vaccum circuit breaker can perform for a 33 KV line in input in 415 volt in output of the transformer ?
1668What is the meaning of the critical speed of a turbine, and what are its effects on the shaft line
1 2959
how can motor both beasrings insulation resistance can be check?
difference bewteen reverse current and alternating current
Explain why is an excess-3 code is called an unweighted code?
sir, plz send me the question regarding DMS gr1 questions of previous year as my exam is on 27/09/08...thanking u in advance...
can i use the six sigma method which is used in management area, in state estimation of power systems?
Calculate the maximum allowable speed on a horizontal curve of radius 350m if the maximum allowable values of the lateral coefficient of friction are 0.14 and the rate of superelevation is 0.08.
hi fiends i am a diploma engineer(mech).now i am preparing for b.e mech part time course. could be send me entrance questions paper fo me .'sureshscad@rediffmail.com'
what is the difference between the voltage of 5 volts capacitor and and 5volts battery?
how can trace the fault in any PCB? what are the steps to find problem & to troubleshoot?
A company canteen needs an automated system for its food and beverage management. The canteen receives food and beverage items from different distributors. All the non perishable items are stored in the store-room and the perishable items are put in the fridge. The manager should be able to add, delete or update food and beverage items onto the system and perishable and non perishable item details are to be stored separately. Both waiters and the cooks should be able to update the perishable items, but only the cooks should be allowed to update the non perishable items. Both cooks and waiters are not allowed to add or delete any items that are entered. identify the Schema, Table , Fields
What is the difference between a gun and a rifle and what advantage does a spinning bullet have?
we are going to install a solar PV site and how can we calculate PV Solar Panel Efficiency, can anybody tell me complete method for its calculation.
what is BPM in concrete demolition hammers. what is better a higher value or lower
Q.1:What protection will be used on HT and LT side of 33/0.4 KV, MVA transformer. Indicate capacities of protective device to be used. Q.2:Which types of back-up protections are used in the power transformers? What do you understand by the term over travel in the relay? Q.3:How star and delta connected winding transformer are provided from earth fault