Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Analytical Chemistry Interview Questions
Questions Answers Views Company eMail

perchloric acid&glacal acetic acid both are acids but reaction is complete in volumetric titrations.how?

1 11284

what is the cleaning validation?

BioPlus,

1 9667

acetic acid is weak acid & perchloric acid is strong acid.but how perchloric acid is soluble in acetic acid

AVT, Hetero,

3 11917

What is polymorphism?which type of compounds exhibits polymorphism?

Torrent Pharma,

2 9665

what is the basic principle of conductivity meter

Hetero,

4 29553

Column selection in HPLC method development?

1 13176

How to prepare ppm solution of Nacl form its salt?

5 69177

what is mean by assay?

6 21801

why we are doing seal wash and needle wash?

3 16245

which functional group we can detect in IR?

3 12428

what is mean by UOD?

2 11496

what is mean by content uniformity?

5 10997

today i am doing calibration of HPLC. when i inject the blank it was going on -ve.(bleow then zero) why?

3 10704

what are the sources in ELSD,PDA, RI and UV Detectors?

1 8190

in karl fischer reagent which solvent is used for dissolving iodine sulphur dioxide and imidazole

Strides,

4 11510


Post New Analytical Chemistry Questions

Un-Answered Questions { Analytical Chemistry }

How require to perform linearity as per ANVISA? What are the acceptance criteria?

1334


How they found 1mL of K.F reagent is equivalent to 5mg of water and if we change the composition of K.F reagent, is it can neutralize more amount of water?

1778


A ha tc is actual defination of retention time?

1617


some product having water content method with pyridine and ethylene glycol mixture instead of methanol? how they are selecting and methanol is not suitable solvent how ?

2653


which batch require to use for analytical method validation?

805


if rsd failed then what require to do?

836


why multimedia dissolution require to do?

830


How to calibration of the uv spectroscopy and its test?

1196


In the HPLC Calibration done wavelength accuracy done between 200nm-280nm .but not done remaining 300-400nm not done ?

925


In the isomers,enantiomers give the only physical properties present such that no chemical properties present.

2221


what is mean by dissolution biowaiver study?

933


How to determine water content of bis tetrazole amine mono ammonium salt

3486


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1596


calibrtion procedue of LC-MS

2710


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3864